Security Datasheet

OpticPrep™ PreSaturated Wipe (UFI)
Conforms to Regulation (EC) No. 1907/2006 (REACH), Annex II, as amended by Commission Regulation (EU)
2020/878
SECTION 4: First aid measures
Notes to physician
Treat symptomatically. Contact poison treatment specialist immediately if large
quantities have been ingested or inhaled.
:
Specific treatments
No specific treatment.
:
Promptly isolate the scene by removing all persons from the vicinity of the incident if
there is a fire. No action shall be taken involving any personal risk or without
suitable training. Move containers from fire area if this can be done without risk.
Use water spray to keep fire-exposed containers cool.
Hazardous combustion
products
Hazards from the
substance or mixture
Decomposition products may include the following materials:
carbon dioxide
carbon monoxide
Flammable liquid and vapour. Runoff to sewer may create fire or explosion hazard.
In a fire or if heated, a pressure increase will occur and the container may burst, with
the risk of a subsequent explosion. The vapour/gas is heavier than air and will
spread along the ground. Vapours may accumulate in low or confined areas or
travel a considerable distance to a source of ignition and flash back.
Fire-fighters should wear appropriate protective equipment and self-contained
breathing apparatus (SCBA) with a full face-piece operated in positive pressure
mode. Clothing for fire-fighters (including helmets, protective boots and gloves)
conforming to European standard EN 469 will provide a basic level of protection for
chemical incidents.
Special protective
equipment for fire-fighters
Use dry chemical,
CO₂,
water spray (fog) or foam.
5.1 Extinguishing media
:
:
:
Do not use water jet.
Suitable extinguishing
media
:
Unsuitable extinguishing
media
:
SECTION 5: Firefighting measures
5.2 Special hazards arising from the substance or mixture
5.3 Advice for firefighters
Special protective actions
for fire-fighters
:
6.2 Environmental
precautions
Avoid dispersal of spilt material and runoff and contact with soil, waterways, drains
and sewers. Inform the relevant authorities if the product has caused environmental
pollution (sewers, waterways, soil or air).
Stop leak if without risk. Move containers from spill area. Use spark-proof tools and
explosion-proof equipment. Dilute with water and mop up if water-soluble.
Alternatively, or if water-insoluble, absorb with an inert dry material and place in an
appropriate waste disposal container. Dispose of via a licensed waste disposal
contractor.
Small spill
:
6.3 Methods and material for containment and cleaning up
SECTION 6: Accidental release measures
6.1 Personal precautions, protective equipment and emergency procedures
For non-emergency
personnel
:
For emergency responders
:
No action shall be taken involving any personal risk or without suitable training.
Evacuate surrounding areas. Keep unnecessary and unprotected personnel from
entering. Do not touch or walk through spilt material. Shut off all ignition sources.
No flares, smoking or flames in hazard area. Avoid breathing vapour or mist.
Provide adequate ventilation. Wear appropriate respirator when ventilation is
inadequate. Put on appropriate personal protective equipment.
If specialised clothing is required to deal with the spillage, take note of any
information in Section 8 on suitable and unsuitable materials. See also the
information in "For non-emergency personnel".
:
Date of issue/Date of revision
1/17/2023
Date of previous issue
1/17/2023
Version
57