Material Safety Data Sheet Electro-Wash® PX 1. Product and company identification Product name : Electro-Wash® PX Supplier : Chemtronics 8125 Cobb Center Drive Kennesaw, GA 30152 Synonym Tel. 770-424-4888 or toll free 800-645-5244 : (Formerly CFC-Free Electro-Wash 2000) Trade name : Electro-Wash® PX Manufacturer : Chemtronics 8125 Cobb Center Drive Kennesaw, GA 30152 Code Tel. 770-424-4888 or toll free 800-645-5244 : ES110, ES510, ES5510, ES810L MSDS # : 0213L Validation date : 8/1/2014.
Electro-Wash® PX 2. Hazards identification Eyes : Severely irritating to eyes. Risk of serious damage to eyes. Potential chronic health effects Chronic effects : Contains material that can cause target organ damage. Carcinogenicity Mutagenicity : Contains material which can cause cancer. Risk of cancer depends on duration and level of exposure. : No known significant effects or critical hazards. Teratogenicity : No known significant effects or critical hazards.
Electro-Wash® PX 3. Composition/information on ingredients There are no additional ingredients present which, within the current knowledge of the supplier and in the concentrations applicable, are classified as hazardous to health or the environment and hence require reporting in this section. 4. First aid measures Eye contact Skin contact Inhalation Ingestion Protection of first-aiders Notes to physician : Check for and remove any contact lenses.
Electro-Wash® PX 6. Accidental release measures Personal precautions Environmental precautions : No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilled material. Shut off all ignition sources. No flares, smoking or flames in hazard area. Avoid breathing vapor or mist. Provide adequate ventilation. Wear appropriate respirator when ventilation is inadequate.
Electro-Wash® PX 8. Exposure controls/personal protection Ingredient Exposure limits hexane ACGIH TLV (United States, 4/2014). TWA: 500 ppm 8 hours. TWA: 1760 mg/m³ 8 hours. STEL: 1000 ppm 15 minutes. STEL: 3500 mg/m³ 15 minutes. OSHA PEL 1989 (United States, 3/1989). TWA: 500 ppm 8 hours. TWA: 1800 mg/m³ 8 hours. STEL: 1000 ppm 15 minutes. STEL: 3600 mg/m³ 15 minutes. NIOSH REL (United States, 10/2013). TWA: 100 ppm 10 hours. TWA: 350 mg/m³ 10 hours. CEIL: 510 ppm 15 minutes.
Electro-Wash® PX 8. Exposure controls/personal protection 2,2-dimethylbutane Isopropyl alcohol propyl acetate n-hexane 8/1/2014. TWA: 100 ppm 10 hours. TWA: 350 mg/m³ 10 hours. CEIL: 510 ppm 15 minutes. CEIL: 1800 mg/m³ 15 minutes. ACGIH TLV (United States, 4/2014). TWA: 500 ppm 8 hours. TWA: 1760 mg/m³ 8 hours. STEL: 1000 ppm 15 minutes. STEL: 3500 mg/m³ 15 minutes. OSHA PEL 1989 (United States, 3/1989). TWA: 500 ppm 8 hours. TWA: 1800 mg/m³ 8 hours. STEL: 1000 ppm 15 minutes.
Electro-Wash® PX 8. Exposure controls/personal protection TWA: 50 ppm 8 hours. NIOSH REL (United States, 10/2013). TWA: 180 mg/m³ 10 hours. TWA: 50 ppm 10 hours. OSHA PEL (United States, 2/2013). TWA: 1800 mg/m³ 8 hours. TWA: 500 ppm 8 hours. OSHA PEL 1989 (United States, 3/1989). TWA: 180 mg/m³ 8 hours. TWA: 50 ppm 8 hours.
Electro-Wash® PX 9. Physical and chemical properties Physical state : Liquid. Flash point : -29 C Flammable limits Color : Lower: 1% Upper: 7% : Clear. Odor : Mild. Hydrocarbon. Boiling/condensation point : Weighted average: 79.27°C (174.7°F) Melting/freezing point : Weighted average: -108.7°C (-163.7°F) Relative density : 0.7 Vapor pressure : 26.4 kPa (198 mm Hg) [room temperature] Vapor density : 3 Air = 1 Evaporation rate : <1 10.
Electro-Wash® PX 11.
Electro-Wash® PX 12. Ecological information Ecotoxicity : No known significant effects or critical hazards. Aquatic ecotoxicity Product/ingredient name Result Species Exposure ethanol Acute EC50 17.
Electro-Wash® PX 14. Transport information Regulatory information UN number Proper shipping name Classes PG* Label Additional information DOT Classification UN1993 FLAMMABLE LIQUIDS, N.O.S. (hexane, 2, 3-dimethylbutane) 3 II - TDG Classification 1993 FLAMMABLE LIQUIDS, N.O.S. (hexane, 2, 3-dimethylbutane) 3 II - Mexico Classification 1993 FLAMMABLE LIQUIDS, N.O.S. (hexane, 2, 3-dimethylbutane) 3 II - ADR/RID Class 1993 FLAMMABLE LIQUID, 3 N.O.S.
Electro-Wash® PX 15. Regulatory information DEA List II Chemicals (Essential Chemicals) : Not listed SARA 302/304 Composition/information on ingredients No products were found. SARA 304 RQ SARA 311/312 : Not applicable.
Electro-Wash® PX 15. Regulatory information International lists Chemical Weapons Convention List Schedule I Chemicals : Australia inventory (AICS): All components are listed or exempted. China inventory (IECSC): All components are listed or exempted. Japan inventory: All components are listed or exempted. Korea inventory: All components are listed or exempted. Malaysia Inventory (EHS Register): Not determined. New Zealand Inventory of Chemicals (NZIoC): All components are listed or exempted.
Electro-Wash® PX 16. Other information Copyright ©2001, National Fire Protection Association, Quincy, MA 02269. This warning system is intended to be interpreted and applied only by properly trained individuals to identify fire, health and reactivity hazards of chemicals. The user is referred to certain limited number of chemicals with recommended classifications in NFPA 49 and NFPA 325, which would be used as a guideline only.