User's Manual
Table Of Contents
- General
 - Module introduction
 - Hardware description
 - Approvals
 - CE Approvals (ETSI)
 - FCC Approvals
 - ATEX Approvals
 - Module Pinout
 - Hardware Description
 - Hardware Diagram
 - Interface characteristics
 - Absolute Maximum Ratings
 - Environmental characteristics
 - Recommended operating conditions
 - DC Electrical Characteristics
 - Digital IO Specifications
 - AC Electrical Characteristics
 - Physical Dimensions and Footprint
 - Physical Dimensions
 - Recommended Footprint
 - Soldering Temperature Time Profile (for reflow so
 - Recommended temperature time profile for lead-fre
 - Reliability Test
 - Application Precautions
 - Safety precautions
 - Engineering design and using precautions
 - Storage conditions
 - Packaging
 - Carrier tape
 - Reel
 - Ordering Information
 - Drawing of Product Label
 - Disclaimer
 - RoHS Declaration
 - Data Sheet Status
 - Reference Documents
 - Contact Information
 
SZU06A1 Product Manual
SZU06A1 PM(Rev 2.0)
18
11 Reliability Test
To guarantee the environment adaptability of SZU06A1, we have done the the following
measurements.
Table 11-1 Reliability Test of SZU06A1
No
Test items
Test methods
1
Vibration test
Setting the vibration frequency of 50Hz, amplitude of 1.5mm,
and each side of XYZ vibrates for 20 minutes respectively
2
Shock test
The module is dropped from the height of 50cm to hard floor to
carry out the test for 3 times
3
Heat cycle test
Charged operation of module: start temperature of cycle:
25
℃
-->-40
℃
(30 minutes) -->85
℃
(30 minutes), for 5 cycles
between high and low temperature
4
Moisture test
Module operates at the environment of + 60
℃
and 90% RH for
24 hours
5
Low temperature
cold start test
Module will be powered after placed in the environment of
-40
℃
for 1 hour
6
Low temperature
test
Operating in the environment of -40℃ for 3 * 24 hours
7
High temperature
test
Operating in the environment of +85
℃
for 3 * 24 hours