User's Manual
Table Of Contents
- General
- Module introduction
- Hardware description
- Approvals
- CE Approvals (ETSI)
- FCC Approvals
- ATEX Approvals
- Module Pinout
- Hardware Description
- Hardware Diagram
- Interface characteristics
- Absolute Maximum Ratings
- Environmental characteristics
- Recommended operating conditions
- DC Electrical Characteristics
- Digital IO Specifications
- AC Electrical Characteristics
- Physical Dimensions and Footprint
- Physical Dimensions
- Recommended Footprint
- Soldering Temperature Time Profile (for reflow so
- Recommended temperature time profile for lead-fre
- Reliability Test
- Application Precautions
- Safety precautions
- Engineering design and using precautions
- Storage conditions
- Packaging
- Carrier tape
- Reel
- Ordering Information
- Drawing of Product Label
- Disclaimer
- RoHS Declaration
- Data Sheet Status
- Reference Documents
- Contact Information
SZU06C2 Product Manual
SZU06C2 PM(Rev 2.0)
19
11
Reliability Test
To guarantee the environment adaptability of SZU06C2, we have done the the following
measurements.
Table 11-1 Reliability Test of SZU06C2
No
Test items
Test methods
1
Vibration test
Setting the vibration frequency of 50Hz, amplitude of 1.5mm,
and each side of XYZ vibrates for 20 minutes respectively
2
Shock test
The module is dropped from the height of 50cm to hard floor to
carry out the test for 3 times
3
Heat cycle test
Charged operation of module: start temperature of cycle:
25℃-->-40℃ (30 minutes) -->85℃ (30 minutes), for 5 cycles
between high and low temperature
4
Moisture test
Module operates at the environment of + 60℃ and 90% RH for
24 hours
5
Low temperature
cold start test
Module will be powered after placed in the environment of
-40℃ for 1 hour
6
Low temperature
test
Operating in the environment of -40
℃
for 3 * 24 hours
7
High temperature
test
Operating in the environment of +85℃ for 3 * 24 hours