User's Manual
Table Of Contents
- General
 - Module introduction
 - Hardware description
 - Approvals
 - CE Approvals(ETSI)
 - FCC Approvals
 - ATEX Approvals
 - Module Pinout
 - Hardware Description
 - Hardware Diagram
 - Interface characteristics
 - Absolute Maximum Ratings
 - Environmental characteristics
 - Recommended operating conditions
 - DC Electrical Characteristics
 - Digital IO Specifications
 - AC Electrical Characteristics
 - Physical Dimensions and Footprint
 - Physical Dimensions
 - Recommended Footprint
 - Soldering Temperature Time Profile (for reflow so
 - Recommended temperature time profile for lead-fre
 - Reliability Test
 - Application Precautions
 - Safety precautions
 - Engineering design and using precautions
 - Storage conditions
 - Packaging
 - Carrier tape
 - Reel
 - Ordering Information
 - Drawing of Product Label
 - Disclaimer
 - RoHS Declaration
 - Data Sheet Status
 - Reference Documents
 - Contact Information
 
SZU06C1 Product Manual
SZU06C1 PM(Rev 2.0)
5
2.3
ATEX Approvals
The SZU06C1 ZigBee wireless communication module has been tested to comply with the
ATEX 2014/34/EU regulation about explosion proof products. Intended Use:Zone 2 GAS.
This device meets the following parameters:
i i i i i S
U =3.9V, I =1A, P=0.98W, C =15.32 μF, L =5.64μH, -40 T 80 . ℃ ℃
And it complies with the following standard:
 EN 60079-0:2012+A11:2013
 EN 60079-11:2012
Ex marking:
Certificate number:
When installing the SZU06C1 module into your own product and requiring explosion protection,
please make sure that your product must meet the above explosion-proof parameters and
indicate "Transceiver Module II 3G Ex ic IIC Gc" or similar words outside the final product.
Name And Address Of Notified Body: TÜV SÜD Product Service GmbH
Zertifizierstellen
Ridlerstraße 65
80339 MÜNCHEN
GERMANY
Number Of Notified Body: 0123
Special conditions for safe use:
1. The sign “U“ placed after the certificate number indicates that the certificate must not
be mistaken with a certificate intended for an equipment or protective system. This
partial certification may be used as a basis for certification of equipment or protective
system.