Information

Option Type Max. operating
force (cN)
Max.
pretravel
(mm)
Min.
overtravel
(mm)
Max. move-
ment differen-
tial (mm
Max. rest
position
(mm)
Operating
point
(mm)
Length of
aux. actuator
Code
Without
auxiliary actuator
DC1, 3, 4
DC2
200
340
1,0
1,0
0,6
0,6
0,1
0,1
9,3
9,3
8,4
0,3
8,4
0,3
AA
Switching parameters
Electrical rating and operating life (2)
Electrical rating according to
EN 61058 UL 1054
Electrical life at rated load
acc. to EN acc. to UL
(operations)
Mechanical life Max. opera-
ting force (cN)
Code
6 A 250 V AC 5 A 125 –250 V AC 10.000 6.000 2 x 10
6
200 1
10 (1,5) A, 250 V AC 10,1 A, 125–250 V AC
1/4 HP, 125 V AC
10.000 6.000 1 x 10
6
340 2
0,1 A, 250 V AC 0,1 A 125–250 V AC 50.000 100.000 2 x 10
6
200 3
3 A, 250 V AC 3 A, 125–250 V AC
50.000 6.000 2 x 10
6
200 4*
* DC4 only possible as line version with line diameter 0.5 mm
2
Contact configuration (3)
Contact configuration Code
Ambient temperature 40T85
S.P.S.T.-N.O.
E
S.P.S.T.-N.C.
F
S.P.D.T. G
Ambient temperature 40T120
(with leads 40T105)
S.P.S.T.-N.O.
A
S.P.S.T.-N.C.
B
S.P.D.T. C
4040