Owner`s manual

Page 15For technical questions, please call 1-888-866-5797.Item 68893
SAFETYOPERATIONMAINTENANCE SETUP
General Operating Instructions
1. Connect the air compressor hose to
the Hose Inlet Fitting (45).
2. Plug in and turn on the Cabinet light.
3. Turn on the vacuum of the dust collection
system (sold separately).
Note: When using a vacuum dust collector,
clean the filter periodically to maintain adequate
suction and effectiveness of the vacuum.
4. Open the Door of the Blast Cabinet and place
the workpiece in the center of the Cabinet.
5. Close the door and secure the latch.
6. Set the compressor′s air pressure
between 90 and 125 PSI.
7. Place your hands into the Gloves inside the
Cabinet. Make sure your fingers are in the
proper positions and that you can easily
move your hands and grip objects.
8. Hold the workpiece in one hand, positioning your
fingers so that the glove is not in the way of the
area you will be blasting. While working, reposition
your grip as needed to ensure that all areas of the
workpiece will be contacted with the blast material.
9. Grip the Abrasive Gun with the other hand and
point the nozzle at the bottom of the Cabinet.
10. Squeeze the trigger.
11. Check that the abrasive media is flowing
through the suction hose with no leaks. Release
the trigger and correct any leaks if needed.
Otherwise begin blasting the workpiece.
WARNING! Do not aim the nozzle at your fingers or
the Blast Gloves. If Gloves are punctured or you feel
air blowing in the Glove, replace them immediately.
Do not use a damaged or punctured Glove.
12. If the tool requires more force to accomplish
the task, verify that the tool receives sufficient,
unobstructed airflow (CFM) and increase the
pressure (PSI) output of the regulator up to the
maximum air pressure rating of this tool.
CAUTION! TO PREVENT INJURY FROM
TOOL OR ACCESSORY FAILURE:
Do not exceed the tool's
maximum air pressure rating.
If the tool still does not have sufficient force
at maximum pressure and sufficient airflow,
then a larger tool may be required.
13. When finished, or to check the
progress of your blasting:
a. Release the trigger, lay the workpiece
on the floor of the Cabinet and remove
your hands from the gloves.
b. Turn off the compressor and dust
collection system (if equipped). Wait for
the air inside the Cabinet to clear.
c. Open the Cabinet door and remove the workpiece.
If the workpiece needs more blasting, resume
from step 4 of these operating instructions.
14. To prevent accidents, release the trigger, detach the
air supply, then squeeze and release the trigger once
more to safely discharge any residual air pressure in
the tool. Empty the Funnel of blast media (see User-
Maintenance Instructions section). Clean external
surfaces of the tool with a clean, dry cloth.
Then store the tool indoors out of children's reach.