Datasheet

Installation Instructions CMS Series Columns
7
4. Using key (J), loosely install screw (C) through lock washer
(D), flat washer (E), and outer column (B) into adjustment
hole in inner column (A) (See Figure 3).
NOTE: Two adjustment holes provided in columns >
6"
(152mm) in length. Either adjustment hole can be used
to provide 1" (25mm) adjustment increments.
NOTE: Optional installation similar; not shown.
Figure 3
5. Adjust column (A or B, as applicable) to desired length, then
rotate and lock into position (See Figure 3).
NOTE: Any locking slot can be used to provide 2" (51mm)
adjustment increments.
6. Tighten screw (C) using key (J) (See Figure 3).
7. Install and tighten set screws (standard (F) or security (H),
as desired) using key (G) (See Figure 4).
NOTE: Optional installation similar; not shown.
Figure 4
WARNING: Exceeding the weight capacity can result in
serious personal injury or damage to equipment! It is the
installer’s responsibility to make sure the combined weight of
all components attached to the CMS Series Extension
Column does not exceed 500 lbs (226 kg).
The weight capacity of the CMS Series Extension
Column may be LIMITED to the lowest weight capacity
of any other component located between the CMS
Series Extension Column and the supporting structure!
8. Install and secure projector/display mount to lower end of
column (A or B, as applicable). See instructions provided
with mount.
4
6
5
CDE
B
A
7
F x2
H x2