o> ct CD c CD -!. W 3. o> c CD g. CT USER'S MANUAL CD1 o 3 d Air Conditioner c CQ CD TD 3 Q.
Air conditioners are pieces of high value. In order to ensure your lawful rights and interests, please have the professional technicians to do the installation for you. This Instruction Manual is the universal-purpose version for the models of split wall-mounted air conditioners manufactured by our Co. The appearance of the units that you purchase might be slightly different from the ones described in the Manual, but it does not affect your proper operations and usage.
[Instructions to users] Please read the "Instruction Manual" carefully prior to the use of your air conditioner so as to ensure proper operations. Instructions for Installation Make sure to have the professional after-sale service persons of our company or the authorized dealers to install the units before you use. 1. The units are not to be installed at places where Make sure that the earth leakage-circuit breaker there might be leakage of combustible gases. is installed.
Try to avoid the sunlight and hot air from entering the room. Try to minimize the generation of heat during the operation of cooling. Do not use combusting apparatuses in the air-conditioned room. During the cooling operation, curtains or windowblinds should be used to shade off the sunlight Place the heating sources out of the room. It might lead to the incomplete combustion of i apparatuses.
[The name of each part and its function] Indoor Unit USER'S MANUAL Room temperature detecting probe Air return grid Takes in the indoor air Receiver of remote control signal Lelf/right air flow direction adjusting fin Up/down air flow direction adjusting flap Air blows out from here Removes dust or dirt out of the inlet air Outdoor Unit Refrigerant piping connection Unit operation section [How to close] Push down the air inlet grid and the push both sides of air inlet grid at the bottom.
[Operation and indication sections of remote controller] (OPERATION MODE indicator)-! , ^ Indicates selected operation mode \ Indicates the set temperature, (it doesn't indicate temperature when operation mode is AUTO select.) ^iVs HLI ( Fan speed indicator ) Indicates the selected air ra e. f7T@f%|- Indicates selected flap mode. ;,' ** .
[Use of remote controller] AUTO MODE OPERATION PROCEDURE Operates by selecting automatically the operation mode (DRY,COOL ,or HEAT) depending on the room temperature at starting. With the remote controller pointing the air conditioner. 1 Press the ON/OFF button. When the unit is not at AUTO SELECT mode. Press the MODE button. Set to "AUTO SELECT" Each time the button is pressed ,the operation mode is changed in sequence ,from'C,"(AUTO)1" (COOL).
Air flow direction adjustment procedure -(Adjusting up/down air flow direction )Up/down direction can be adjusted by using the OUT FLAP button on the remote controller. This button , each time pressed , changes the mode in the following sequence: -(2) (3) (4) (5) (AUTO) Change to the OUT FLAP mode. TO change the VANE CONTROL velocity press the FAN SPEED button. Each time the button is pressed.fan speed is changed in sequence, from . [Lo]*i [Mid]«*l[Hi]fS)[AUTO].
PRESENT TIME SETTING PROCEDURE When cells are inserted, the present is automatically set to AM 12:00. EX.:Setto AM 10:30 1 Press the CLK button. Unload the back cover push the clock botton with the tip of a ball pen, etc. The time indicator is flickering and can set the present time. 2 Press the HOUR button. (Set to AM 10:) 3 Press the MIN button. (Set to 30) 4 Press the CLK botton again,then reattach the back cover CD AV poo -'-.----- -,:•- NOTE The timer is set on the basis of the present time.
USER'S It is convenient to set the timer for the time when you go to bed ,when you get home ,when you get up , ect. ( How to set the ON timer ) Press the AUTO START button to set the on timer mode when the AC is in the standby mode. Each time the button is pressed, the ON timer mode alternates between ON and OFF. Set the time of the timer using the HOUR and MIN buttons.
[Methods of Maintenance] The air conditioner must be turned off power before the maintenance is to be carried out. Before the season of operation During the season of operation The cleaning of Ihe air fitter screen (Standard intervals should be once every two weeks). I Check if there are any blocking materials > Remove the air filter screen from the unit. ' in the intake and outlet vents of the indoor » Gently press the two lower ends of and outdoor units. the grid and open it.
[Treatment at service call] Please check the following before requesting after-sale service from your dealer. The air conditioner does not operate at all. Is the time set to "ON" position ? Is the power in an outlet ? |2"7£B Room temperature can't be controlled . (Too cold or too hot) Is there a power failure or a break fuse ? Is the room temperature setting too low or too high? Poor cooling or heating performance . Is the room temperature setting suitable ? /*.
[We hope you will know the following when using the unit] The unit can not be restarted just after shut down . ( RUN lamp is illuminating ) /" (f>'j ^^^^^ < "^ Not operate ' Restart is stopped for 3 minutes after shut down to protect the unit . jflh f Please wait for"1, i 3 minutes . j \ pW^i \y J Three-minute protection timer incorporated in the microcomputer actuates automatically . Except that power is connected , this function does not actuate .
[Installation of electric components] Points of attention • HACK type breaker should be utilized along with proper installation; • Make sure of the applicable voltage and cables or wires for the specific model to be used, before doing the connections; • Read the prompts at the terminal board for wiring. Make sure the wiring is done correctly. • Pay attention to the poles of the signal terminal and connect the terminals to match the identification numbers.