Specifications
39 
Over 
temperature 
1. The internal temperature is higher than
specified normal value 
2. Find a way to reduce the ambient temperature.
3. Or move the inverter to a cooler environment 
4. If it is not effective, call local service 
Relay Failure 
DC INJ High 
EEPROM 
Failure 
SCI Failure 
High DC Bus 
Low DC Bus 
Ref 2.5V Fault 
DC Sensor 
Fault 
GFCI Failure 
1. Disconnect ALL PV (+) or PV (-) 
2.  Wait for few seconds 
3.  After the LCD switches off, reconnect and 
check again 
4.  If the message reappears call your local  
service 
z  If there is no display on the panel, please check PV-input connections.  
If the voltage is higher than 150V, call your local service. 
z  During periods of little or no sunlight, the PV-Inverter may continuously 
start up and shut down. This is due to insufficient power generated to 
operate the control circuits. 