B04C Type Intelligent Display Meter Instructions
Catalogue 一、PRODUCT INTRODUCTION........................................................ 3 1.PRODUCT NAME.................................................................................................3 2.PRODUCT MODEL................................................................................................................. 3 3.NORMAL DISPLAY AREA.................................................................................................. 3 4.KEY DEFINITION.......................................
一、PRODUCT INTRODUCTION 1. Product name Intelligent display controller 2. Product model B04C_MEEBIKE 3.
①Headlight display:display the on / off status of the headlights, and display the identification when the system headlights are on. ②Maintenance tips:display maintenance prompt flag. ③Navigation function:the mobile app is connected to the bluetooth of the instrument, and the instrument displays the identification when the mobile app starts navigation. ④Bluetooth function :display the Bluetooth on / off status, and display the identification after successfully connecting the bluetooth.
.Routine operation B04 C_M EE BI K E _ _ Type meter provides 4 theme styles UI and 3 languages for users to set, this specification is based on theme 1 , English version as an example. " Press button > 2.5S " is replaced by " long press " , and " short press button < 0.5S " is replaced by "click " . 1 On / Off long-pressing the " on-off button ”,the meter will be powered on and work. In power on state, long-press the " on-off button ”,the system can be powered down.
3 Headlight/Backlight Switch Turn on the lights: long press the " + " button when the light is off, the headlights on the screen will turn on, and the controller will be notified to turn on the lights. Turn off the light: long press the " + " button when the light is on, the headlight logo on the screen does not disappear, but only dims, and the controller will be notified to turn off the lightsat the same time .
In boost mode, the boost sign is displayed dynamically, vehicle speed is less than 6km/h, loose the key to stop the boost state, the screen boosting logo disappears and the static boosting logo state is restored. under static boost 5s,If no key is pressed, it will be automatically set to 0 gear.
1.Meter setting ① Imperial and metric unit conversion Enter " Display Setting " menu , select " Unit " , click " " to enter the setting , after entering the setting , using " + " key or " - " key to select " Metric " / " Imperial " , click " " to save and exit to " Unit " , through " Back " → “ Exit ” exits to the main interface. the unit conversion is shown as below. Note: The equipment defaults to imperial standard. All information in the metric main interface is imperial standard.
Note: any operation within the automatic power off time will be re timed, and the power off will not occur until the operation time reaches the set time.
④ Backlight brightness setting Enter " Display Setting " menu , select " Brightness " by using " + " key or " - " key , select " " to enter the setting , after entering the setting, short press the " + " key or " - " key to select " 25% " / " 5 0 % " / " 7 5 % " / " 10 0 % " , Short press “ ” to save and exit to “ Brightness ”, and exit to the main interface through “ Back ” → “ Exit ” . Backlight Set is shown as below.
2.Information view ① Wheel diameter information —— Enter the “ Information ” menu , using " + " key or " - " key , select " " to enter the setting , then need to enter the password for the first time (the password is 0510). The default wheel diameter is 23inch, and the setting range is 12inch-30inch. through “ Back ” → “ Exit ” _ Exit to the main interface. shown as below.
2. When the unit is mile English system, the speed limit defaults to 20mph and is set to the range of 20-45mph. Click " " to save and exit to "speed limit",through " Back " → " Exit " exit to the main interface.
3.Language selection B04U_MEEMIKE meter provided 3 languages for users to select.Click " " to enter the setting Information list, using“+”key or“-”key to select“Language”,click “ ”enter language selection interface,and using“+”key or“-”key to switch “English”,“Deutsch”and“Espanol”,then short press“ ”to confirm.through “Back”→“Exit”exit to main interface.The language selection is shown as below. 4.UI select B04C_MEEMIKE meter provided 4 different styles _ UI interface for the user to select.
5.Password setting ①Set the opening password———— click the " " key to enter the setting information list,using“+”key or“-”key select“Password”option,select“ ”to confirm. enter Password option interface,cursor select “Start Password”(Start Password status is off),and click “ ” to confirm , When prompted to enter the password , using " + " key or " - " key to switch the number " 0 - 9 " , click " " to switch the number, confirm the number in the current cursor.
successfully.. after the password is cancelled successfully, the interface automatically jumps to the original setting interface. through “ Back ” → “ Exit ” exit to the main interface. The operation steps are shown as below.
to the original setting interface,through " Back " → " Exit " exit to the main interface. The operation steps are shown as below.
6.Bluetooth connection Click the " " key to enter the setting information list , and select the " Bluetooth " option by using " + " key or the " - " key,click " " to confirm , enter Bluetooth QR code interface , which can be accessed through the mobile phone APP scan the QR code to bind the device. After binding the device , the device interface automatically jumps to the main interface , and the Bluetooth function logo lights up . The operation steps are shown as below.
FCC Caution. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.