Each column of cubes requires four anchor bolts. Each anchor bolt must be capable of withstanding
a pullout force of 500 lbs. After installing the anchors, verify the pedestal is level.
Warning! Failure to comply with the following could result in death or serious injury.
• The amount of external support required depends on the size of the display wall. Support
structures must be designed and implemented by a qualified installer and comply to local area