Specifications
Cube Installation and Setup
Entero HB Rear-Access Cube Installation and Setup Manual 20
020-101007-04 Rev. 1 (12-2014)
The gap cards included in the User Kits should be used during assembly. Two 0.5mm cards can
be stacked to make a 1.0mm gap.
Thermal increase
Hygroscopic increase
Thermal Increase
(Degrees Celcius)
Recommended Gap Size (mm)
50” 67” 70” SX 70” HD 72” WU 80”
0 0.10.10.10.10.10.1
2 0.10.20.20.20.20.2
4 0.20.30.30.40.40.4
6 0.40.50.50.50.50.6
8 0.50.60.60.70.70.7
10 0.6 0.8 0.8 0.9 0.9 0.9
12 0.7 0.9 1.0 1.1 1.1 1.1
14 0.8 1.1 1.1 1.2 1.2 1.3
16 0.9 1.2 1.3 1.4 1.4 1.5
18 1.0 1.4 1.4 1.6 1.6 1.6
20 1.2 1.6 1.6 1.8 1.8 1.8
Hygroscopic
Increase (percent)
Recommended Gap Size (mm)
50” 67” 70” SX 70” HD 72” WU 80”
0 0.10.10.10.10.10.1
5 0.10.10.10.10.10.1
10 0.1 0.1 0.1 0.1 0.1 0.1
15 0.1 0.1 0.1 0.1 0.1 0.1
20 0.1 0.2 0.2 0.2 0.2 0.2
25 0.2 0.2 0.2 0.2 0.2 0.2