User manual

BASIC OPERATION
CP2000-X User Manual 3-41
020-100031-01 Rev . 1 (03-2009)
Figure 3.26. Admin:Lamp Menu Functions
Table 3.10. Summary of Admin:Lamp
Menu Functions
ADMIN:LAMP MENU FUNCTIONS
Lamp Type Select which lamp is installed in the projector. Correct lamp type sets
the corresponding range of power available. NOTE: The lamp must be
OFF in order to set Lamp Type.
Footlamberts Calibration Activate each text box to automatically drive the lamp at its minimum
or maximum power. Record light measured at the screen for both
extremes—this defines a range of footlamberts possible. Light
readings (fL) appearing elsewhere in TPC will then be interpolated
from this range.
Cable Length Define the length of the high-current DC cables connected between
your lamp ballast and projection head. Adjustment range is 2-30m
(6½-100 ft.) in 1m increments.
NOTES: 1) For manual operation (i.e., non-automated). 2) In order to use the TPC
software originally shipped with the projector, the installer typically connects a
laptop and uses Christie’s DCP Librarian setup software to download all necessary
configuration files to the projector for use at the TPC.
To change to a new source—i.e., a new presentation or display—do the following
(See Figure 3.27):
Make sure the CP2000 and TPC are both powered up and operating normally
On the Touch Panel Controller (TPC), select the Main menu tab
On the Main menu, press the desired channel button—the image will update
accordingly
Selecting a Displa
y
(Starting a Presentation)