Instruction manual

Installation and Setup
CP2215 Quick Start Guide 14
020-101295-01 Rev. 2 (05-2014)
All SCCI inputs require a pulse input of 50ms to several seconds to operate reliably. Inputs are 5V
resistor current limited LED’s inside of optocouplers.
The open-collector Health Output (PIN 8) circuit only draws power when a failure occurs or an
interlock is activated.
Connect Power
1. If the projector is operating, turn it off and disconnect it from AC power.
2. Loosen the threaded bolt on the ground lug on the AC receptacle on the rear corner of the
projector.
3. Remove 15 mm of insulated covering from both ends of the protected earth wire.
8 Health output Out Playback stops and the open collector registers low when one
of these interlocks is activated:
• Lamp Door
• Lamp Blower
• Extractor
• Tamper
• Marriage
• Ballast Communication
Playback functions normally when the open collector registers
high and all CineLink and Lamp interlocks are not activated.
9 Ground Out Ground.
The dedicated earth wire can only be installed by a Christie accredited service technician or
an electrician. The protected earth wire must be green/yellow 12 AWG minimum. See Power
Requirements on page 29 for power requirements. Failure to comply could result in death or
serious injury.
• Do not operate the projector if the AC power supply and cord are not within the specified
voltage and power range. Only use the power cord supplied with the projector. Failure to
comply could result in minor or moderate injury.
• A dedicated, protected earth wire must be installed on the projector before it can be
connected to power. You must use a 20A branch circuit breaker for Input A. Install the
projector near an AC receptacle that is easily accessible. Failure to comply could result in
minor or moderate injury.
PIN Signal Name Direction Description