Instruction manual

Maintenance
CP2215 Quick Start Guide 28
020-101295-01 Rev. 2 (05-2014)
4. Rinse the filter thoroughly by holding it on an angle under cool running water. The air flow
arrow on the side of the filter should face down.
5. Repeat steps 3 and 4 if the filter still appears dirty.
6. Shake the filter over a container until most of the water is removed.
7. Place the filter on its edge on a flat, stable surface and allow it to dry thoroughly.
8. To confirm that the filter is dry, place it over a dry paper towel and shake it. If the paper towel
remains dry, the filter can be installed in the projector.
9. Record the date the filter was cleaned.
10. Replace the filter following the instructions for the specific filter. See Inspect the Card Cage
Filter on page 27.
Replace the Lens
The lens seals the projection head, preventing contaminants from entering the main electronics
area. Do not operate the projector without a lens installed. Install a lens plug when you install or
transport the projector.
1. Tap and hold the red power button on the TPC Main panel to turn the lamp and
projector off.
2. Allow the lamp to cool for a minimum of 15 minutes.
3. Disconnect the projector from AC power or turn the circuit breaker off.
4. Install the lens cap and turn the lens clamp to the open position.
5. If necessary, remove the 2 cap screws securing the lens to the lens mount using a hex key.
6. Pull the lens out of the lens mount and then install a small lens cap on the rear of the lens.
7. Remove the small rear cap from the new lens. Keep the front cap on.
8. Align the tabs on the lens plate with the lens mount. Insert the lens until it connects with the
magnets on the mount. When the lens contacts the magnetic plates it is seated correctly.
9. Secure the lens clamp by rotating it clockwise.
10. Tighten the lens mount cap screws for added stability.
11. Remove the lens cap from the front of the lens.