User`s manual

Lamp Replacement Instructions
2 of 4
WARNING
Wait at least 5 minutes after powering down or switching lamp operation
modes to allow the lamp to cool sufficiently before removing.
Figure 1.
2. Remove the single screw from the lamp door
you want to open. NOTE: The amber window
on the door (Figure 1.) should be dim. If it
“glows” then the lamp in this compartment is
still on. Manually switch to the other single
lamp operation mode to cut power to the
lamp before replacing. (Figure 2.)
3. Swing the lamp door open. (Figure 2.)
4. Using a screwdriver or fingers, turn the three lock screws on the lamp module counter-
clockwise a quarter turn each to “unlock” it. (Figure 3.)
5. Using the two finger guides molded into the
lamp housing, pull the lamp straight out of
the projector. (Figure 3.) The lamp module
disconnects from the terminal block located
at the back of the lamp compartment.
6. Discard the lamp using approved disposal
methods for your area. NOTE: Mercury
containing lamps must be treated as
hazardous waste if discarded in large
volumes.
Figure 2.
Figure 3.