Product data

Chapter 5. Logical partition migrations 103
hdisk1 Available 00-08-02 MPIO Other FC SCSI Disk Drive
hdisk2 Available 00-08-02 MPIO Other FC SCSI Disk Drive
hdisk4 Available 00-08-02 MPIO Other DS4K Array Disk
hdisk5 Available 00-08-02 MPIO Other DS4K Array Disk
hdisk6 Available 00-08-02 MPIO Other FC SCSI Disk Drive
hdisk7 Available 00-08-02 MPIO Other FC SCSI Disk Drive
# lscfg -vl fcs0
fcs0 U78A0.001.DNWGCV7-P1-C4-T1 FC Adapter
Part Number.................10N8620
Serial Number...............1B80904DC3
Manufacturer................001B
EC Level....................A
Customer Card ID Number.....5759
FRU Number.................. 10N8620
Device Specific.(ZM)........3
Network Address.............10000000C9738E84
ROS Level and ID............02C82774
Device Specific.(Z0)........1036406D
Device Specific.(Z1)........00000000
Device Specific.(Z2)........00000000
Device Specific.(Z3)........03000909
Device Specific.(Z4)........FFC01231
Device Specific.(Z5)........02C82774
Device Specific.(Z6)........06C12715
Device Specific.(Z7)........07C12774
Device Specific.(Z8)........20000000C9738E84
Device Specific.(Z9)........BS2.71X4
Device Specific.(ZA)........B1F2.70A5
Device Specific.(ZB)........B2F2.71X4
Device Specific.(ZC)........00000000
Hardware Location Code......U78A0.001.DNWGCV7-P1-C4-T1
The remaining commands gather data that will be compared with the
post-migration state to validate that the disks on the source system are in fact the
same disks as on the destination partition.
The tail command lists out the last two lines of the /etc/hosts file and the df
command shows us that the partition has a /data file system mounted. Finally,
the ls command shows us a data file that was created for this exercise to validate
the post-migration data disk.
# tail -2 /etc/hosts
192.168.100.92 p2_411
192.168.100.91 p1_411
# df -k