Product data

Chapter 5. Logical partition migrations 141
Figure 5-25 Virtual Fibre Channel adapter added to client profile
6. Dynamically remove the virtual SCSI server adapters from the Virtual I/O
Server and add a virtual Fibre Channel adapter.
On the Virtual I/O Server
In the following steps, the adapters defined in the previous steps will be
configured and the mappings to the disk from the Virtual I/O Server to the client
partition created:
7. Run the cfgdev command to remove the virtual SCSI server vhost adapters
removed earlier and to configure the virtual Fibre Channel adapter. The
following lsdev command shows us the virtual Fibre Channel adapter that
was configured.
$ lsdev -virtual | grep vfc
vfchost0 Available Virtual FC Server Adapter
8. Map the physical Fibre Channel adapter to the virtual Fibre Channel adapter.
The lsdev command that follows shows us all the Fibre Channel adapters on
the Virtual I/O Server. The dual-ported 8 GB Fibre Channel adapter shown is
our NPIV capable adapter. Thus, this is the one that must be used. Our cables