System information
Parts and Module Replacement Christie/Mirage/DLV/Matrix
020-100012-01 Rev. 1 (04/07) 11
Air Filters
(5 minutes for both)
Two air filters are used in this projector; one located at the front and one on the left
hand side (when viewed from the front). It is recommended both filters be replaced
when the lamp in the projector is replaced or sooner if the operating environment is
extremely dusty. A clean air filter ensures the projector’s optical components
remain relatively clean.
DO NOT clean or reuse filters.
Use the clean filters provided in the
service kit only.
To remove and replace the front air
filter:
1. Loosen the single screw securing
the front air filter cover.
2. Remove the cover and pull the
filter out.
To remove and replace the side air
filter:
1. Loosen the three (3) captive screws
from the side filter cover.
2. Remove the cover and pull the
filter out.
When replacing either air filter, make
sure to install it with the wired side
facing in.
Airflow Sensor
(9 minutes)
The airflow sensor is located on the lamp blower. The placement of this sensor is
critical in that it monitors the amount of airflow and temperature and will cause the
projector to shutdown if it is not positioned correctly.
NOTE: Make sure you use the correct sensor for your projector model. Different
sensors are used in 500W/1000W and 1200W models. Refer to the parts list at the
beginning of this booklet for the correct kit number. Replacement instructions
apply to all models.
To remove and replace:
1. Remove the top cover. See Top Cover.
2. Disconnect the airflow sensor harness.
Figure 3. Removing Air Filters
Front f
Side
f