System information

Christie/Mirage/DLV/Matrix Parts and Module Replacement
34 020-100012-01 Rev. 1 (04/07)
Figure 45. Remove the Rear IR Sensor
Lamp
Use only the Christie approved Lamp and Filter Kit for your specific projector
model.
WARNING
Handle lamp with care.
High-pressure lamp may explode if not handled
properly or dropped. Wear protective clothing and
safety goggles when handling lamps.
Use only Christie approved lamps provided in the
Lamp and Filter Service Kits for your projector.
1. Press to power down the projector. Wait at least five (5) minutes to allow
the internal cooling fans to stop before unplugging the projector. This wait
period is also required to allow the lamp to sufficiently cool before handling.
WARNING
Always power down and unplug the projector prior to
servicing.
Allow the lamp to cool before handling.
2. Using a screwdriver, loosen the two (2) screws from the lamp door located at
the back of the projector just below the input panel. (Figure 46.)
Figure 46. Remove Lamp Door
3. Pull (out) and turn the lamp lock lever a quarter turn counter clockwise to the
“unlock” position. (Figure 47.)
Gloves
Required