System information
Parts and Module Replacement Christie/Mirage/DLV/Matrix
020-100012-01 Rev. 1 (04/07) 49
NOTE: The appearance and cable connections of your projector may differ
slightly from those in Figure 70.
When replacing the TCPD/HDPD, use the appropriate Interconnections
drawing for your projector model to correctly reconnect harnesses. See Pages
51 or 52.
UV Filter
(5 minutes)
The UV filter is located and mounted to the end of the optical tray. It is accessible
through the lamp compartment. To remove and replace:
1. Remove the lamp. See Lamp Replacement.
2. Looking into the lamp compartment, locate the UV filter on the left hand side.
It is mounted to the optical tray with three (3) screws. Remove the screws and
the filter. (Figure 71.)
Figure 71. UV Filter
When replacing, locate the marking on the UV filter. It may be a dot on one side or
an arrow mark on the edge. This marking identifies the coated surface. The UV
filter must be installed with the coated surface facing out towards the lamp.
NOTE: The arrow on the edge of the filter points in the direction of the coated
surface. In this case, insert the filter so the arrow points to the inside of the lamp
compartment.
Gloves
Required