Table 3.9 System Error Codes
Code Description
GENERAL
12 Software error. Contact dealer/factory.
13 CRC error in flash ROM. Download new software.
14 Engineering-only programming is complete. Call Christie, replace TIPM.
15 Attempting to download s/w code without being in boot mode
16 Invalid interrupt. Power off/on. If persists, contact dealer/factory.
17 User has forced system to stay in boot mode
18 Attempting to program boot mode without jumper
LAMP / BALLAST
20 The lamp is unexpectedly on (likely a ballast and/or wiring problem)
22 One or more high-current lamp cables is not connected
26 Lamp door is open (interlock)
27 Lamp cannot ignite
28 Lamp has turned off unexpectedly
29 Lamp ballast is overheated
2C Lamp communications fault; ballast is not detected
SENSORS for COOLING
40 Lamp has shut down due to fan failure
46 The red TEC (DMD) has overheated
48 The blue TEC (DMD) has overheated
49 The prism has overheated
4C Projector has shut down due to critical error
4D Integrator has overheated
4E Inadequate lamp air intake rate (interlock)
4F Inadequate air exhaust rate (interlock)
FANS (note: there are no Fans 1 or 2 in this projector)
53 Fan 3 has failed (side [rear] intake fan)
54 Fan 4 has failed (side [front] intake fan)
55 Fan 5 has failed (lamp exhaust fan)
56 Fan 6 has failed (LAD fan)
57 Fan 7 has failed (card cage fan)
58 Fan 8 has failed (heat exchanger fan — for liquid cooling system)