User manual

5-12 TVC-500 Operation Manual
020-100539-01 Rev. 1 (08-2010)
Section 5: Troubleshooting
ERROR: Invalid 1394
GUID (Invalid
electronic serial
number)
No electronic serial num-
ber is stored with the sys-
tem.
To assign a serial number, select Security >System IDs in
the Computer Setup (F10) Utility.
ERROR: Invalid electronic
serial number (no
number)
No electronic serial num-
ber is stored with the sys-
tem
To assign a serial number, select Security >System IDs in
the Computer Setup (F10) Utility.
ERROR: An unsupported
processor is
installed. System
halted
Unsupported processor
detected.
Replace the processor.
ERROR: A processor
requiring too
much power is
installed. System
halted
Unsupported processor
detected.
Replace the processor.
ERROR: Mixing proces-
sors with different
power require-
ments. This is not
supported. Sys-
tem halted.
Mixed type processors
detected.
Replace the processors with matched processors.
Invalid electronic
serial number
Incorrect serial number
registered in the system.
Use the Computer Setup (F10) Utility to reset the serial
number.
Mixing proces-
sors with different
power require-
ments. This is not
supported. Sys-
tem halted
Mixed type processors
detected.
Replace the processors with matched processors.
Mixing Two Dif-
ferent Processor
Types MP and
DP!!!
Mixed type processors
detected.
Replace the processors with matched processors.
Network Server
Mode Active and
No Keyboard
Attached
Keyboard not detected. Verify that a functioning keyboard is attached to the work-
station.
Processor initial-
ization fails!!!
Processor defective. Replace the processor.
The installed
CPUs have differ-
ent voltage
requirements.
This is not sup-
ported. System
halted.
Mixed type processors
detected.
Replace processors with matched processors.
Table 5.3 Post Error Messages
Screen Messages Probable Cause Recommended Action