SC103 Gateway User Manual 2010-08-29 Table of Contents 1. Copyright and Confidential.................................................................................1 2. Disclaimer .............................................................................................................1 3. Revision Record....................................................................................................1 4. Introduction ..................................................................................
SC103 Gateway User Manual 2010-08-29 1. Copyright and Confidential The information contained in this document or diagram is confidential and proprietary to Chromagic Technologies Ltd. Co. This information may not be distributed or used for any purpose other than the evaluation of Chromagic’s solutions, nor may it be disclosed to any party without the prior written consent from Chromagic. All Rights Reserved. 2.
SC103 Gateway User Manual 2010-08-29 4. Introduction The gateway is a transceiver which belongs to the member of U-Net series and is fully compatible with any U-Net enabled devices. It is reliably and remotely control and monitor your U-Net enabled devices. Whether you’ll be on site and logging in through your network, or away from the premises, logging in through the internet, you’ll always have access to control and monitor your security system.
SC103 Gateway User Manual 2010-08-29 5.2. Buttons There are two buttons in the HSC04, one is the reset button (near the dummy USB socket), and another is the connection button (near the RJ-45 socket). Reset Button: This button will reboot the system. If the system is halting, the user can press this button. Note: The HSC04 has the battery power inside, if the DC power be cut off, it will auto switch to use the battery power. So the device is still halting.
SC103 Gateway User Manual 2010-08-29 5.3. LED LED1 LED2 LED3 LED4 Figure 2: The definition of the LEDs. We define the function name of these LED. LED1: Power LED. LED2: Connection LED. LED3: Network 1 LED. LED4: Network 2 LED. 5.3.1. Power LED The The The The The The green light is on: power is on. red light is on: Flash is writing data. red light is flash once every 5 seconds: system time is not synchronize after boot up. 5.3.2.
SC103 Gateway User Manual 2010-08-29 Blinking in red and green: The firmware upgrade function is enabled in bootloader runtime. The green light is blinking in second: (0.5s On, 0.5s Off) The system is in the binding mode. The green light is turn on 2 seconds and turn off 2 seconds: The system is inclusion other U-Net device successful. The green light is blinking: (0.1s On, 0.1s Off) If the system is binding timeout, it will persistence in 4 seconds.
SC103 Gateway User Manual 2010-08-29 6. How to search the device? In default, the HSC04 will enable the DHCP function to get the IP address. If the DHCP function is failed, you will see the “Connection LED” is light on red. In this situation the HSC04 will set the default IP address 192.168.1.222. Static IP: 192.168.1.222 Netmask: 255.255.255.0 Gateway: 192.168.1.1 DNS1: 192.168.1.
SC103 Gateway User Manual 2010-08-29 Figure 5: Gateway Finder Timeout 7. Web Configuration Using the browser (IE or Firefox) to access the HSC04, just enter the URL http://(IP Address)/ in browser, The first time access the HSC04 web server, it will request login, the default user name is “webadmin” and the password is “admin”. Figure 6: First Time Access the HSC04 Web Server. Chromagic Technologies Co., Ltd.
SC103 Gateway User Manual 2010-08-29 7.1. Network Settings Set the IP address using the DHCP or the static IP address. Figure 7: Network Settings DHCP Click the “Manual Setting the IP address” to set the static IP address. Figure 8: Network Settings DHCP Chromagic Technologies Co., Ltd.
SC103 Gateway User Manual 2010-08-29 After setting OK, don’t forget to press the “submit” button. Figure 9: Network Setting Submit After 20 seconds, the browser will connect to new IP address. And you must re-login. Figure 10: Browser Auto Connect to New IP Address Chromagic Technologies Co., Ltd.
SC103 Gateway User Manual 2010-08-29 Figure 11: The Browser Connected to New IP Address 7.2. System Settings The system settings will set the NTP function and the message server. Figure 12: System Settings Chromagic Technologies Co., Ltd.
SC103 Gateway User Manual 2010-08-29 7.2.1. NTP Settings The HSC04 has not the RTC, which means if the power is off, the system time will be reset or stopped. So at the boot time, the HSC04 will synchronize the system time with the NTP server. The default NTP settings: NTP function enable: Yes NTP Server: clock.via.net Time Zone: 0 If connect to NTP server failed, it will try again after 1 hour. If synchronize the time OK, after 4 hours it will synchronize again.
SC103 Gateway User Manual 2010-08-29 7.2.2. Gateway Registration If this function is enabled, after boot up OK, the HSC04 will send the registration information to the server every 150 seconds. Figure 14: System Setting Gateway Registration 7.2.3. U-Net Message Forward If this function is enabled, when the U-Net devices report the state to the HSC04, it can forward the message to the server. Chromagic Technologies Co., Ltd.
SC103 Gateway User Manual 2010-08-29 Figure 15: System Setting Message Notification 7.3. VPN Settings A VPN (Virtual Private Network) is a network that uses a public telecommunication infrastructure, such as the Internet, to provide remote offices or individual users with secure access to their organization's network. Figure 16: The VPN link. The HSC04 will use the OpenVPN to provide the VPN function. The user can see the OpenVPN state or settings from the browser. Chromagic Technologies Co., Ltd.
SC103 Gateway User Manual 2010-08-29 Figure 17 VPN Settings There are two secret keys in OpenVPN, one is for OpenVPN, and another is for OpenSSL. The keys do not store in the Linux file system. They will be store in the Flash, and encrypted. Before running the OpenVPN, these keys must be existed. The user can upload the key by “Update” page. Just upload the key file instead of the firmware file. Figure 18: Upload the Key File Chromagic Technologies Co., Ltd.
SC103 Gateway User Manual 2010-08-29 Figure 19: Upload Key OK If the VPN function is enabled and established. The connection LED will turn the green light on. Chromagic Technologies Co., Ltd.
SC103 Gateway User Manual 2010-08-29 7.4. Language Settings Change the web page language to display. Figure 20: Language Settings Figure 21: Language Change to French. Chromagic Technologies Co., Ltd.
SC103 Gateway User Manual 2010-08-29 Figure 22: Language Change to Chinese 7.5. Update Settings There are two firmware upgrade function in the HSC04. One is in the bootloader runtime; another is in the Linux runtime. Normally, the user always upgrades the firmware in the Linux runtime. Unless the system occur error or the user want to manual enable the upgrade function, in these case it will operate in the bootloader runtime. Chromagic Technologies Co., Ltd.
SC103 Gateway User Manual 2010-08-29 7.5.1. In Linux Runtime Figure 23: The Upgrade Page in the Linux Runtime Choose the firmware file and click the “Update” button. It will start to upload the firmware and write to the flash. It will start to count down. At this time, the user should not cut off the power of the HSC04. Figure 24: Upgrade and Count Down to Reboot. Chromagic Technologies Co., Ltd.
SC103 Gateway User Manual 2010-08-29 After the count down, the browser will auto re-connect to the homepage of the HSC04. When the firmware is writing to the Flash, the power LED is light on red. 7.5.2. In the Boot Time In the boot time, if the HSC04 found error image cause to fail boot. The HSC04 will auto into the upgrade mode. At this moment, the connection LED will flash on green and red.
SC103 Gateway User Manual 2010-08-29 Figure 26: The count down in the bootloader runtime. After the count down, the browser will re-connect to 192.168.1.222. But if the HSC04 has enabled the DHCP function, the IP will be changed, the user needs to connect to the newest IP manually. 8. U-Net Bind The bind is an operation of the U-Net, it is for include the other U-Net devices to the HSC04. Here will describe how to use the connection button to operate the binding function.
SC103 Gateway User Manual 2010-08-29 Binding timeout: If enter the binding mode over 30 seconds, it will occurs the timeout, the connection LED will quickly flashing in 4 seconds. The user can read the device information from the browser. Ex: http://192.168.1.100/unet/deviceinfo.cgi?uid=0 It will list all device information in the HSC04.
SC103 Gateway User Manual 2010-08-29 FEDERAL COMMUNICATIONS COMMISSION INTERFERENCE STATEMENT This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.