Electric Heater User Manual

(Supersedes PG417-2)
PG417-3
SK
161-048460-001
OCTOBER, 2004
4
Type SKR Infrared Comfort Heater
© 2010 Chromalox, Inc.
Specifications – Table A
GENERAL
Chromalox Type SKR radiant heaters are designed for indoor
installation only, and are to be ceiling mounted with such spacing
between heaters to project heat radiation downwards to maintain
comfort level within the radiation field.
Before Installing
1. Open carton and remove heater at the place of installation.
Mounting clamps are in parts bag in carton.
2. Check nameplate volt and watt rating against your power sup-
ply voltage and heating requirements of your installation. This
nameplate is located on one end of the heater.
MOUNTING (See Figure 1)
1. Layout heater locations to the desired heat affected work area.
2. Minimum spacing to walls and ceiling are —
A. One foot (12”) from top of heater to ceiling.
B. Two feet (24”) from side or end of heater to adjacent walls.
3. Minimum safe height above floor level for combustible mater-
ial is 6 feet (72”). However, if ceiling height permits, more
practical height is 8 feet or more to avoid high radiation inten-
sities at head level when one stands directly below heater.
INSTALLATION
Combustible Surfaces
Protective Grille
12” Min.
24”
Min.
24”
Min.
Maximum
Radiation
Within
60° Included
Angle
A
72” Min.
B
3-11/16”
2-3/4”
3/8” Conduit
Figure 1
Single Phase Power Circuit Amps Dimensions (In.)
Model Watts 120V 208V 240V 275V 480V A B
SKR-2083 0800 6.7 3.9 3.4 24
3
/8 22
7
/8
SKR-3113 1100 9.2 5.3 4.6 30
5
/8 29
1
/8
SKR-4183 1800 8.7 7.5 6.6 46
5
/8 45
1
/8
SKR-5253 2500 12.00 10.50 9.1 5.3 61
3
/8 59
7
/8
SKR-6303 3000 14.40 12.50 10.90 6.3 73
3
/4 72
1
/4
SKR-7363 3600 17.30 15.00 13.10 7.5 85
3
/4 84
1
/4

Summary of content (4 pages)