Specification

IFM 05/14/18
®
INSTANT-FLOW MICRO - STANDARD FLOW
ELECTRIC TANKLESS WATER HEATER - POINT OF USE
Get Started www.mgispecbuilder.comConfigure products and create specs with ease.
SELECTION SUMMARY
& APPROVAL FOR
MANUFACTURING
Model Number & Options_____________________________________________________________________Quantity_______________
Company_______________________________________________________________________________________________________
Contact_________________________________________________Title____________________________________________________
Signature
(Approval for
Manufacturing)__________________________________________________________________Date ____________________________
PH. 800-447-4962
626-937-4270
FAX 626-937-4279
www.chronomite.com
Chronomite Laboratories assumes no responsibility for use of void or suspended data. © Copyright Chronomite Laboratories, Inc.
Member of Morris Group International, City of Industry, CA Please visit www.chronomite.com for most current specifications.
TECHNICAL DIMENSIONS
INSTALLATION DIAGRAM
¥
The microprocessor adjusts the heater's power for variations in flow
rates, inlet water temperature and pressure to assure the selected
factory preset water temperature.
¥
240V models when operated at 220V will have approximately a 15%
wattage decrease.
¥
120V models when operated 110V will have approximately a 15%
wattage decrease.
¥
Factory setting of 110°F or above require cold water mixing at the
hand wash faucet.
¥
Microprocessor limits temperature increase according to the pre-
selected temperature.
¥
M40/277 not certified to CAN/CSA STD C22.2 No. 88
GENERAL NOTES:
Minimum Operating Flow Rate: 0.65 GPM
Dimensions: 6-1/4" (H) x 9-5/8" x 2-3/4"
Weight: 5 lbs.
®
INSTANT-FLOW MICRO - LOW FLOW
Materials: Rugged cast aluminum housing
Celcon plastic element assembly
with nichrome coils
Housing Color: White
Minimum Operating Pressure: 25 PSI
Maximum Pressure: 150 PSI
Maximum Water Temperature: 160°F
Maximum Ambient Operating Temperature: 140°F
Listing: UL, IAPMO, UPC, ADA, ETL
Maximum Operating Pressure: 80 PSI
Chronomite Laboratories assumes no responsibility for use of void or suspended data. © Copyright Chronomite Laboratories, Inc.
Member of Morris Group International, City of Industry, CA Please visit www.chronomite.com for most current specifications.
Notes:
1. Heater to be installed below the level of all hot water outlets serviced by the Heater.
2. Diagram shown with standard 3/8” Compression Fitting. Optional 1/2” NPT Male water
connections available.
Electrical Supply Wire
Instant-Flow Micro Heater
Electrical Supply Conduit
3/8” Hot Water Outlet
Electrical Junction Supply Box (Optional)
3/8” Comp. x 1/4” NPT Fittings (supplied)
3/8” Cold Water Inlet
2095-1 Disconnect Switch (Optional)
Dual Outlet Stop, 3/8” Comp. Outlet
Connections
1
6
2
3
8
4
5
7
2A
OR
2
6
4
3
1
2A
5
8
7
WIRING CONNECTION
Conduit
"GND" is
Earth Ground
Hot
Hot or
Neutral
ATTENTION:
Unit must be hard wired.
NOTE: Heaters are single phase. All tests
are measured at the output of the heater.
Refer to Local Code
for Wire size
10
1
8
"
1
1
8
"
1
5
16
"
1
1
8
"
2
3
4
"
5
3
4
"
1
4
"
1
4
"
9
5
8
"
3
5
16
"
2"
6
1
4
"
2
3
4
"
6
1
4
"
Ø1
3
32
" Access Hole
4x Ø
3
16
"
Rear Electrical
Knock-Out
Temperature Adjust
Knob (ADJ) Option