Instructions / Assembly

Note: MP =Male Pipe FP = female Pipe Comp = Compression Fittings
Page 2
OPERATION INSTRUCTIONS
Turn the hot water fixture to activate the flow switch. The flow switch activates at .4 gallons per minute (GPM) and
deactivates at .35 gallons per minute (GPM).
If you increase the flow rate of the water above .5 GPM the water temperature will become cooler. Cold water can always
be mixed just as with a conventional system if using a two handle faucet.
Once you decrease the flow rate to .35 GPM the unit will deactivate. It is not advisable to operate the heaters at .35
GPM.
>Periodically inspect the supply lines, connections and heater for any moisture, corrosion or other potential preventable
problems.
HOW INSTANT-FLOW MICRO WORKS
The cast alloy case houses a series of ingeniously designed coils that instantly heat water as it flows through the vessel. A
unique power switch automatically applies electrical current to the coils when hot water is requested. The electrical current
is not applied when the water is not in use. The microprocessor is internally preset at the factory to maintain a constant
output temperature with varying flow rates.
FLOW CONTROL SPECIFICATIONS
Material: Chrome plated, brass housing.
Threading: MODEL L-412 & LP-412 has male/female threads for faucets
with 15/16” female or 55/64” male threads.
*Flow controls are adaptable to other thread configurations.
Please call factory If adapter is needed.
FLOW CONTROL MODELS
Model GPM Vandal Proof Models GPM
L-412 (Dual) 0.5 L-910VR (Female) 0.5
LP-412 (Dual) 0.5
FIGURE 2
FLOW CONTROL INSTALLATION (See Parts List #9 & #10)
FACTORY SET TEMPERATURES
Choose from the following:
104 ºF
110 ºF see *** below
120 ºF see *** below
* Other Temperature Settings are
available upon request up to
140 ºF
** Temperature Settings are not