Product Brochure

16
CHRONOMITE LABORATORIES, INC. • 800-447-4962 • WWW.CHRONOMITE.COM
POINT-OF-USE ELECTRIC TANKLESS WATER HEATERS
INSTANTFLOW
®
MICRO
MODEL M SERIES
POINTOFUSE ELECTRIC TANKLESS WATER HEATER
INSTANT FLOW®  MICRO™ M SERIES
LOW FLOW
˚F TEMPERATURE RISE @
MODEL ACTIVATION GPM VOLTS KW AMPS/Ø 90°C WIRE 0.35 GPM 0.5 GPM 1.0 GPM 1.5 GPM 2.0 GPM
M-20L/120 0.35 120 2.40 20 12 AWG 47 33 --- --- ---
M-30L/120 0.35 120 3.60 30 10 AWG 70 49 25 --- ---
M-20L/208 0.35 208 4.16 20 12 AWG 81 57 28 --- ---
M-30L/208 0.35 208 6.24 30 10 AWG 90 + 85 43 28 21
M-40L/208 0.35 208 8.32 40 8 AWG 90 + 90 + 57 38 28
M-20L/240 0.35 240 4.80 20 12 AWG 91 + 66 33 22 ---
M-30L/240 0.35 240 7.20 30 10 AWG 90 + 90 + 49 33 25
M-40L/240 0.35 240 9.60 40 8 AWG 90 + 90 + 66 44 33
M-15L/277 0.35 277 4.15 15 14 AWG 81 57 28 --- ---
M-20L/277 0.35 277 5.54 20 12 AWG 90 + 76 38 25 ---
M-30L/277 0.35 277 8.31 30 10 AWG 90 + 90 + 57 38 28
INSTANT FLOW®  MICRO™ M SERIES
STANDARD FLOW
˚F TEMPERATURE RISE @
MODEL ACTIVATION GPM VOLTS KW AMPS/Ø 90°C WIRE 0.65 GPM 1.0 GPM 1.5 GPM 2.0 GPM
M-30/208 0.65 208 6.24 30 10 AWG 66 43 28 21
M-40/208 0.65 208 8.32 40 8 AWG 87 57 38 28
M-30/240 0.65 240 7.20 30 10 AWG 76 49 33 25
M-40/240 0.65 240 9.60 40 8 AWG 90 + 66 44 33
M-30/277 0.65 277 8.31 30 10 AWG 87 57 38 28
M-40/277 0.65 277 11.08 40 8 AWG 90 + 76 50 38
Note : Wire size based on national electric code - All wire must be sized based on licensed electrician per the local code
Note: Factory temperature settings available - (ADJ) Field Adjustable temperature available 104 -125 degrees.
Note: For Sanitation optional max factory setting of 140 degrees available
2.4  11 KW
MODEL M SERIES