Instructions / Assembly

Page 1
IMPORTANT NOTES:
Air in the heater may cause the elements to burn out. If the water lines are drained,
allowing air into the heater, be sure to follow the following start-up procedure:
1. Turn off electrical supply at circuit breaker.
2. Turn on water supply.
3. Expel all air from lines and heater.
4. Turn on electrical power supply at circuit breaker.
FIGURE 1 HEATER INSTALLATION
Faucet flow controls must be attached to the faucet to allow the water heating system to operate more effectively
(See Fig. 2, pg. 3 for installation).
Item Part No. Names Qty Description
1. M-_ _L Chronomite Instant-Flow Micro Heater 1 Models shown in Table 1
2. Electrical junction box
3. Electrical conduit ½” conduit, length as required
4. Electrical wire Wire size shown in Table 1
5. Dual outlet angle valve 1 ½” FPx7/16” comp.x3/8 comp., Brass
Craft P/N R2701R-RGH
6. Fitting (supplied) 2 3/8” comp x ¼”MP
7. Copper or flex tubing 1 3/8”OD, 5” long (keep short)
8. Copper or flex tubing 3/8” OD, length as required (keep short)
9. L-412 Faucet flow control, dual thread 1 Supplied with Low Flow Heater
OR (see figure #2) M-20L, M-30L
10. LP-412 Faucet flow control, dual thread 1 Supplied with Low Flow Heater
M-20L, M-30L
Hot
Sin
k
Mounting
Flange
Cold
#1
#2
#3
Conduit
#5
#6
#7
#9 , #10
#4
#8