Table 3 Transducer Block Configurations (Page 15)
FILTER_GVF_SPIKE_FILTER_LENGTH
Unsigned
Char
R/W
This parameter is used when the device is 'Holding' a
previous measurement due to a new measurement with
bad quality. The definition of this parameter is the
required number of consecutive measurements with bad
quality before the device enters the 'No Flow' state and
displays dashes.
FILTER_GVF_SPIKE_FILTER_UP_COUNT
Unsigned
Char
R/W
Each time a measurement with bad quality is made 'Up
Count' is added to an entity called the quality counter. If
the quality counter becomes less than or equal to zero
then the present measurement is displayed. If the
quality counter becomes greater than or equal to ('Filter
Length' x 'Up Count') then the device is forced into a 'No
Flow' condition and displays dashes.
FILTER_GVF_SPIKE_FILTER_DOWN_COUNT
Unsigned
Char
R/W
Each time a measurement with good quality is made
'Down Count' is subtracted from the quality counter. If
the quality counter becomes less than or equal to zero
then the present measurement is displayed. If the
quality counter becomes greater than or equal to ('Filter
Length' x 'Up Count') then the device is forced into a 'No
Flow' condition and displays dashes.
FILTER_GVF_SPIKE_FILTER_PERCENTAGE Float R/W
After 'Percent Len' measurements with good quality
have been displayed a new measurement with good
quality is deemed valid and displayed when the
difference between the maximum and minimum of the
present measurement and ('Percent Len' - 1) previous
consecutive measurements is less than the
measurement range (default of 27fps for Flow) times
('Percent' / 100).
FILTER_GVF_SPIKE_FILTER_FILT_PCT_WINDOW_LEN
Unsigned
Char
R/W
After 'Percent Len' measurements with good quality
have been displayed a new measurement with good
quality is deemed valid and displayed when the
difference between the maximum and minimum of the
present measurement and ('Percent Len' - 1) previous
consecutive measurements is less than the
measurement range (default of 27fps for Flow) times
('Percent' / 100).
Copyright © 2010 CiDRA Corporate Services Page 5-16
20958-01 Rev 02