Printer User Manual

Programming Reference
VERSAJET
For ITF (Interleaved 2 of 5) (m = 5, 70) process
Start code and stop code are added automatically.
Check digits are not calculated and added.
For CODEBAR (NW-7) (m = 6, 71) process
Start code and stop code are not added automatically. Transmit data including the
codes.
Specify the start code (ASCII = “A“ ~ “D,” / Hex = 41H ~ 44H, / Decimal = 65 ~ 68) at
beginning of the data (d1).
Specify the stop code (ASCII = “A“ ~ “D,” / Hex = 41H ~ 44H, / Decimal = 65 ~ 68) at
end of the data (dk or dn).
Start code or stop code (ASCII = “A“ ~ “D,” / Hex = 41H ~ 44H, / Decimal = 65 ~ 68)
cannot be specified in bar code data.
Check digits are not calculated and added.
For CODE93 (m = 72) process
Start code and stop code are added automatically.
Check digits (2 character) are calculated and added automatically.
Special character HRI is processed as follows:
The printer prints an HRI character " " as start and stop character.
The printer prints HRI characters " + an alphabetic character" as a control character
(unprinted character).
166