BARCODE IMAGER Programming Manual International Edition, Rev.
Revision History Rev. No. Released Date Rev.B Beta Apr. 16, 2009 Description First Release Programming Manual FuzzyScan Page 22 Page 25 Page 46 Code 128/EAN-128 Setting – Modify ISBT Concatenation Off option code to “4” and ISBT Concatenation On option code to “5”. GS1 Databar Setting – All GS1 databar default values are changed to Enable. Add “Symbology ID Table”. June 22, 2009 Page 34 Page 37 Add “Presentation Scanning Mode”. Add “Time Delay to Low Power Mode”. Rev.B2 Aug.
Revision History Rev. No. Released Date Rev. B6 May 27, 2010 Page 33 Baud Rate – Add 57.6K BPS and 115.2K BPS. Jun 25 , 2010 Page 17 Page 38 Add “UPC/EAN Security Level”. Add “Immediate” parameter (option 5) to "Time Delay to Low Power Mode" and change the default value from 5 seconds to immediate. Programming Manual FuzzyScan Rev. B7 Description Rev. B8 Sep 29 , 2010 Page 15,16 Add “ Supplement Scan Voting”. Page 17 Add “EAN Supplement Control”.
Revision History Page 36 Rev. C3 Rev. C4 Jul 22, 2011 Nov 04, 2011 Cancel the parameter "User defined value (seconds)” of “Serial response time -out”. Page 44 Add “Laser Aiming Control” function. Page 14 Add “Codabar Check Digit Settings” Page 38 Cancel 1 parameter of “Code 39/Code 128 Emulation”. (Disable standard code 39 emulation - -0) Rev. C5 Jan 02, 2012 Page 38 Change of default setting to Enable standard code 39 skip emulation in “Code 39/Code 128 Emulation”.
Revision History Rev. D3 Aug. 20, 2013 Rev. D4 Sep. 06, 2013 Rev. D5 Programming Manual FuzzyScan Rev. D6 Mar. 06, 2014 Feb. 06, 2015 Page 12 Modify “Readable Bar Code Setting” section Page 76 Modify “Symbology ID Table” Page 73 Modify “1D Bar Code Symbology” and “2D Bar Code Symbology” Page 32 Change “Expanded GS1 DataBar” to “GS1 DataBar Expanded”. Page 32 Add “GS1 128 Limited Security Level” Page 80 Add “USB HID Legacy Mode” Quick Set.
© Copyright Cino Group © Copyright PC Worth Int’l Co., Ltd Cino makes no warranty of any kind with regard to this publication, including, but not limited to, the implied warranty of merchantability and fitness for any particular purpose. Cino shall not be liable for errors contained herein or for incidental consequential damages in connection with the furnishing, performance, or use of this publication. This publication contains proprietary information that is protected by copyright.
Table of Contents Getting Started Getting Familiar with Your FuzzyScan 1 Connecting to Your Host 1 Using Accessories 2 Configure Your FuzzyScan Programming Manual FuzzyScan Bar Code Programming Manual 3 Programming Procedures 4 Host Interface Selection 8 Symbology Reading Control 9 Keyboard Interface Control 41 Serial Interface Control 46 Wand/Laser Emulation Control 51 Operation Control 53 Condensed DataWizard 69 Appendix Symbology ID Table 77 Keyboard Function Code Table 79
Getting Started Getting Familiar with Your FuzzyScan Connecting to Your Host Thank you for choosing Cino FuzzyScan Bar Code Scanner. All FuzzyScan scanners deliver world-class performance for a broad range of applications to unleash your productivity. FuzzyScan scanners support USB, PS/2(DOS/V) Keyboard Wedge and RS-232 Serial interfaces. Please choose your desired interface cable, then plug it into the cable interface port of the scanner and connect it to the host.
Getting Started Using Accessories Thanks to the auto-sense design, the scanner is capable of switching between presentation scanning and hand-held scanning automatically while working with SmartStand. But please note that this feature is not available for F500 series scanners. You can enhance productivity of your workforce by using various accessories to fulfill a wide variety of application demand.
Configure Your FuzzyScan Bar Code Programming Menual The FuzzyScan bar code commands are specially designed Proprietary bar code labels which allow you to set the FuzzyScan internal programming parameters. There are System Command, Family Code and Option Code for programming purpose.
Configure Your FuzzyScan Programming Procedures Programming Manual FuzzyScan As you scan the bar code command to select the desired parameters, information about the final selected parameters represented by the bar code commands are stored in the FuzzyScan’s internal Flash Memory ASIC or memory. If you turn off the unit, the Flash Memory ASIC or non-volatile memory retains all programming options. You need not re-program the FuzzyScan if you want to keep the existing configurations in the next power on.
Configure Your FuzzyScan Program & End System List, Group & Master Default Scan “PROGRAM” Scan “SYSLIST” FuzzyScan will enter programming mode, and inhibit all non-programming functions. revision number to host via selected host interface, FuzzyScan will list the product information and Programming Manual FuzzyScan then issue the completion beeping.
Configure Your FuzzyScan Single scan selection Scan “PROGRAM” Scan One of Family Codes Multiple scans selection Scan “PROGRAM” Enter programming mode. Select one of desired Select one of desired Scan programming families. One of Family Codes programming families. 1. Select one or several Select one option code of Scan One of Option Codes Enter programming mode. Scan One or Several Option Codes desired parameter. option codes to select desired parameters. 2.
Configure Your FuzzyScan Cycling scan selection Dual level selection Scan “PROGRAM” Scan One of Family Codes Scan “PROGRAM” Enter programming mode. Select one of desired Scan One of Family Codes programming families. Cycling select one or Scan One of Option Codes desired parameters as Programming Manual FuzzyScan (2nd) Scan One or Several Option Codes Scan “FIN” Finish cycling selection. of desired parameters. 1. Select one or several parameters. 2.
Configure Your FuzzyScan Host Interface Selection PROGRAM F_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Symbology Reading Control ♦ User Defined Symbol ID ♦ Programming Manual FuzzyScan PROGRAM F_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Symbology Reading Control ♦ User Defined Symbol ID ♦ Programming Manual FuzzyScan PROGRAM F_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Symbology Reading Control ♦ Symbology ID Transmission ♦ Programming Manual FuzzyScan PROGRAM F_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Symbology Reading Control ♦ Readable Bar Code Setting ♦ PROGRAM Family Code Selection Readable Symbology Setting Programming Manual FuzzyScan Remember to scan “FIN” to terminate this selection. But if you select the “Auto”, FuzzyScan will terminate this selection automatically. F_DEFAULT P.
Configure Your FuzzyScan Symbology Reading Control ♦ Readable Bar Code Setting ♦ PROGRAM Family Code Selection F_DEFAULT P.C Parameter Selection Option Code Programming Manual FuzzyScan CS Australian Post B0 Readable Symbology Setting CS British Post B1 CS Intelligent Mail barcode B3 CS Japanese Post B4 CS KIX Post B5 CS Planet Code B6 CS Postnet B8 If your application is known, you may select those known symbologies only to increase the reading speed and decrease the possibility of reading error.
Configure Your FuzzyScan Symbology Reading Control ♦ Code 39/Code 32 Setting ♦ Programming Manual FuzzyScan PROGRAM F_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Symbology Reading Control ♦ Code 39 Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Code 39 Security Level SS SS SS SS Parameter Selection Level 0 Level 1 Level 2 Level 3 Option Code 0 1 2 3 Programming Manual FuzzyScan Code 39 Security Level The scanner offers four levels of decode security for Code39 bar codes: Level 0: If you are experiencing misread of poorly-printed or serious out-of-spec. bar codes in level 1, please select level 0.
Configure Your FuzzyScan Symbology Reading Control ♦ Codabar/NW-7 Setting ♦ Programming Manual FuzzyScan PROGRAM Family Code Selection P.
Configure Your FuzzyScan Symbology Reading Control ♦ UPC-A & UPC-E Setting ♦ Programming Manual FuzzyScan PROGRAM F_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Symbology Reading Control ♦ UPC-A & UPC-E Setting ♦ Programming Manual FuzzyScan PROGRAM F_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Programming Manual FuzzyScan UPC/EAN Security Level The scanner offers three levels of decode security for UPC/EAN bar codes: Level 0: If you are experiencing misread of poorly-printed or out-of-spec. bar codes, especially in characters 1, 2, 7, and 8 in level 1, please select level 0. Selection of this security level may significantly impair the decoding ability of the scanner.
Configure Your FuzzyScan Symbology Reading Control ♦ EAN Setting ♦ PROGRAM Family Code Selection EAN Setting Programming Manual FuzzyScan EAN Supplement Setting Supplement Scan Voting F_DEFAULT P.
Configure Your FuzzyScan Programming Manual FuzzyScan The Supplement Scan Voting is the number of times the same UPC/EAN with 2/5 supplement digits has to be decoded before it is transmitted. It is helpful when decoding a mix of UPC/EAN symbols with and without supplement digits. This function is effective when you select UPC/EAN with only 2 supplement digits, UPC/EAN with only 5 supplement digits or UPC/EAN with 2/5 supplement digits. The default value is Level 3.
Configure Your FuzzyScan Symbology Reading Control ♦ EAN Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Symbology Reading Control ♦ UCC Coupon Extended Code Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C UCC Coupon Extended Code SS SS Parameter Selection Disable UCC Coupon Extended Code Enable UCC Coupon Extended Code Option Code 0 1 Programming Manual FuzzyScan UCC Coupon Extended Code When UCC coupon extended code function is enabled, scanner decodes UPC-A barcodes starting with digit “5”, EAN-13 barcodes starting with digit “99” and GS1-128 Coupon Codes.
Configure Your FuzzyScan Symbology Reading Control ♦ IATA & Interleaved 2 of 5 Setting ♦ Programming Manual FuzzyScan PROGRAM F_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Symbology Reading Control ♦ Code 25 Family Setting ♦ Programming Manual FuzzyScan PROGRAM F_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Symbology Reading Control ♦ Code 11 & Code 93 Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection Code 11 Setting SS SS SS SS SS SS SS Disable Code 11 Enable Code 11 Disable check digit verification Select 1-check digit verification Select 2-check digit verification Disable check digit transmission Enable check digit transmission Code 11 Min.
Configure Your FuzzyScan Symbology Reading Control ♦ MSI/Plessey Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection MSI/Plessey Setting SS SS SS SS SS SS SS Disable MSI/Plessy Enable MSI/Plessy Select MOD 10 check digit Select MOD 10-10 check digit Select MOD 11-10 check digit Disable check digit transmission Enable check digit transmission MSI/Plessey Min.
Configure Your FuzzyScan Symbology Reading Control ♦ Code 128 Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection Code 128 Setting SS SS SS SS Disable Code 128 Enable Code 128 ISBT Concatenation Off ISBT Concatenation On Code 128 Min. Length SS MS Default (01) 01-Maximum Option Code 0 1 2 3 FIN (2 digits) Scan 2 digits from the option code chart in Appendix; then FuzzyScan will terminate this selection automatically. Programming Manual FuzzyScan Code 128 Max.
Configure Your FuzzyScan Symbology Reading Control ♦ GS1-128 Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection GS1-128 Setting SS SS Disable GS1-128 Enable GS1-128 GS1-128 Min. Length SS MS Default (01) 01-Maximum Option Code 0 1 FIN (2 digits) Scan 2 digits from the option code chart in Appendix; then FuzzyScan will terminate this selection automatically. Programming Manual FuzzyScan GS1-128 Max.
Configure Your FuzzyScan Symbology Reading Control ♦ UK/Plessey Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection UK/Plessey Setting SS SS SS SS SS SS SS SS Disable UK/Plessey Enable UK/Plessey Select UK/Plessey Standard Format Select UK/Plessey CLSI Format Disable Convert X to A-F Enable Convert X to A-F Disable check digit transmission Enable check digit transmission UK/Plessey Min.
Configure Your FuzzyScan Symbology Reading Control ♦ Telepen Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection Telepen Setting SS SS SS SS SS SS Disable Telepen Enable Telepen Select Telepen Numeric mode Select Telepen Full ASCII mode Disable check digit transmission Enable check digit transmission Telepen Min.
Configure Your FuzzyScan Symbology Reading Control ♦ GS1 DataBar Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Symbology Reading Control ♦ Composite Codes, Codablock F PDF417/MicroPDF417 & Setting ♦ PROGRAM Family Code Selection P.C Composite Codes Setting SS SS SS SS Parameter Selection Disable composite codes Enable composite codes UPC Composite Mode: UPC never linked UPC Composite Mode: UPC always linked F_DEFAULT Option Code 0 1 2 3 If UPC Composite Mode: UPC never linked is selected, UPC barcodes are transmitted whether MicroPDF417 symbol is detected or not.
Configure Your FuzzyScan Symbology Reading Control ♦ Code 16K & Code 49 Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection Code 16K Setting SS SS Disable Code 16K Enable Code 16K Code 16K Min. Length SS MS Default (01) 01-Maximum Option Code 0 1 FIN (3 digits) Scan 3 digits from the option code chart in Appendix; then FuzzyScan will terminate this selection automatically. Programming Manual FuzzyScan Code 16K Max.
Configure Your FuzzyScan Symbology Reading Control ♦ QR Code Setting ♦ Programming Manual FuzzyScan PROGRAM F_DEFAULT Family Code Selection P.C QR Code Setting SS SS QR Code Min.
Configure Your FuzzyScan Symbology Reading Control ♦ Data Matrix Setting ♦ PROGRAM Family Code Selection Data Matrix Setting Data Matrix Min. Length F_DEFAULT P.
Configure Your FuzzyScan Symbology Reading Control ♦MaxiCode Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C MaxiCode Setting SS Disable MaxiCode 0 SS Enable MaxiCode 1 SS MS Default (01) 01-Maximum MaxiCode Min. Length Parameter Selection Option Code FIN (3 digits) Scan 3 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. Programming Manual FuzzyScan MaxiCode Max.
Configure Your FuzzyScan Symbology Reading Control ♦ Aztec Code Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection Aztec Code Setting SS SS Disable Aztec Code Enable Aztec Code Aztec Code Min. Length SS MS Default (01) 01-Maximum Option Code 0 1 FIN (4 digits) Scan 4 digits from the option code chart in Appendix; then FuzzyScan will terminate this selection automatically. Programming Manual FuzzyScan Aztec Code Max.
Configure Your FuzzyScan Symbology Reading Control ♦ Australian Post, US Planet, US Postnet, British Post & Japan Post Setting ♦ Programming Manual FuzzyScan PROGRAM Parameter Selection F_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Symbology Reading Control ♦ Netherlands KIX Code, Intelligent Mail & Korea Post Code Setting ♦ Programming Manual FuzzyScan PROGRAM Parameter Selection F_DEFAULT Family Code Selection P.C Netherlands KIX Code Setting SS SS Disable Netherlands KIX Code Enable Netherlands KIX Code 0 1 Intelligent Mail Setting (USPS 4CB/One Code) SS SS Disable Intelligent Mail Enable Intelligent Mail 0 1 Korea Post Code Setting SS SS Disable Enable Length fixed in 6 characters.
Configure Your FuzzyScan Keyboard Interface Control ♦ Keyboard Layout (Language) Setting ♦ Programming Manual FuzzyScan PROGRAM F_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Keyboard Interface Control ♦ Record Suffix, Preamble, Postamble, FNC1 Transmit & Caps Lock ♦ PROGRAM Family Code Selection P.C Parameter Selection Record Suffix SS SS SS SS SS SS None RETURN TAB SPACE ENTER (Numeric Key Pad) User defined character (1 character) Preamble SS MS None 1-15 characters F_DEFAULT Option Code 0 1 2 3 4 5, (00-7F) FIN [00-7F], [FIN] Maximum 15-character input; scan “FIN” to terminate this selection.
Configure Your FuzzyScan Programming Manual FuzzyScan FNC1 Symbol Char. Transmit: When this function is enabled and the FNC1 is contained in scanned data, the scanner transmits the FNC1 to the host. Chart of theFNC1 is provided in Appendix- Keyboard Function Code Table. When the scanner interface is set to keyboard, the scan code is converted to corresponding key function before it is transmitted.
Configure Your FuzzyScan Keyboard Interface Control ♦ Delay Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Intermessage Delay SS MS Parameter Selection None 1-99 (x5) msec. Option Code FIN (2 digits) Scan 2 digits from the option code chart in Appendix; then FuzzyScan will terminate this selection automatically. Intercharacter Delay SS MS None 1-99 (x5) msec.
Configure Your FuzzyScan Keyboard Interface Control ♦ Emulation Setting, Key Pad Emulation & Upper/Lower Case Setting ♦ PROGRAM Family Code Selection P.C Function Key Emulation SS SS Parameter Selection Enable ASCII 00-31 code as keyboard function code output Ctrl-Output F_DEFAULT Option Code 0 1 Programming Manual FuzzyScan Refer to Appendix – Keyboard Function Code Table for details.
Configure Your FuzzyScan Serial Interface Control ♦ Record Suffix, Preamble ,Postamble Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C STX/ETX Control SS SS Parameter Selection Option Code Disable STX/ETX transmission Enable STX/ETX transmission 0 1 STX/ETX are two characters used to indicate the starting and ending of the total data frame transmitted via serial interface.
Configure Your FuzzyScan Serial Interface Control ♦ Delay Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Intermessage Delay SS MS Parameter Selection None 1-99 (x5) msec. Option Code FIN (2 digits) Scan 2 digits from the option code chart in Appendix; then FuzzyScan will terminate this selection automatically. Intercharacter Delay SS MS None 1-99 (x5) msec.
Configure Your FuzzyScan Serial Interface Control ♦ Protocol, ACK/NAK Setting ♦ Programming Manual FuzzyScan PROGRAM F_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Serial Interface Control ♦ Response Time-out Setting, Baud Rate Setting ♦ PROGRAM Family Code Selection P.C Serial Response Time-out SS SS SS SS SS SS SS SS SS SS SS SS SS None 200 mseconds 500 mseconds 800 mseconds 1 second 2 seconds 3 seconds 4 seconds 5 seconds 8 seconds 10 seconds 15 seconds 38.4K BPS 0 1 2 3 4 5 6 7 8 9 A B0 SS SS SS SS SS SS SS 19.2K BPS 9600 BPS 4800 BPS 2400 BPS 1200 BPS 57.6K BPS 115.
Configure Your FuzzyScan Serial Interface Control ♦Data Frame Setting ♦ PROGRAM Family Code Selection F_DEFAULT P.
Configure Your FuzzyScan Wand/Laser Emulation Control (F & L Series) PROGRAM ♦ Output Polarity, Signal State, Margin/Module Time ♦ Family Code Selection P.C Output Polarity SS SS Parameter Selection High level (5Vdc) on Bar (low level on Space) Low level (0Vdc) on Bar (high level on Space) F_DEFAULT Option Code 0 1 Determine the output voltage level for both bar and space. Initial Signal State SS SS High Level (5Vdc) Low Level (0Vdc) 0 1 Determine the initial state of output voltage level.
Configure Your FuzzyScan Wand/Laser Emulation Control (F & L Series) PROGRAM Family Code Selection ♦ Output Polarity, Signal State, Margin/Module Time ♦ P.
Configure Your FuzzyScan Operation Control (F & L Series) ♦ Operation Mode Setting ♦ PROGRAM Family Code Selection P.C Parameter Selection Programming Manual Option Code SS Low Power mode 0 SS Trigger mode 1 Presentation mode SS 2 SS Alternative mode 3 SS Flash mode 4 SS Force mode 5 Toggle mode SS 6 Diagnostic mode SS 7 SS Level mode 8 Low Power Mode (Low Power Triggering): The scanner goes into idle state after scanning the bar code.
Configure Your FuzzyScan Operation Control (F & L Series) ♦Presentation Control, Scan Rate, Flash Duty ♦ Programming Manual FuzzyScan PROGRAM Parameter Selection F_DEFAULT Family Code Selection P.C Option Code Presentation Control SS SS SS Presentation mode Flash mode Force mode 0 1 2 Scan Rate Control SS SS Dynamic Fixed 0 1 Flash Duty Cycle SS SS SS SS 1/2 duty cycle 2/3 duty cycle 3/4 duty cycle 4/5 duty cycle 0 1 2 3 L680/L780 laser imagers don’t support this function.
Configure Your FuzzyScan Operation Control (L Series) ♦ Laser Imager, LED Illumination Control ♦ PROGRAM Family Code Selection P.C LED Illumination Control SS SS Parameter Selection Always on Intelligent Mode F_DEFAULT Option Code 0 1 Only available for L Series. LED Illumination Delay SS SS SS SS SS 100 ms 150 ms 200 ms 250 ms 300 ms 0 1 2 3 4 Programming Manual FuzzyScan Only available for L Series.
Configure Your FuzzyScan Operation Control (F & L Series) PROGRAM ♦ Laser Aiming Control , 1D Barcode Reading Direction♦ ♦ Family Code Selection P.C Laser Aiming Control SS SS Parameter Selection F_DEFAULT Option Code Disable Enable 0 1 Only available for L Series.
Configure Your FuzzyScan Operation Control (A Series) ♦ Operation , Presentation and Illumination Control♦ PROGRAM Family Code Selection P.
Configure Your FuzzyScan Operation Control (A Series) Programming Manual FuzzyScan PROGRAM ♦ Aiming Control, Delay Aiming & Decode Aiming Control ♦ Family Code Selection P.C Aiming Control SS SS SS Regular Aiming Intelligent Aiming Delay Aiming Control 0 1 2 Delay Aiming Time-out Control SS SS SS SS SS SS SS SS SS SS SS SS 200 ms 400 ms 800 ms 1 sec 1.5 secs. 2 secs. 3 secs. 4 secs.
Configure Your FuzzyScan Operation Control (A Series) PROGRAM Family Code Selection ♦ Center Alignment, Unique Bar Code Reporting ♦ Unique Bar CodeParameter Reporting, Batch Reading♦ P.
Configure Your FuzzyScan Operation Control (A Series) PROGRAM Family Code Selection P.C Batch Reading SS ♦ Batch Reading ♦ F_DEFAULT Unique Bar CodeParameter Reporting, Batch Reading♦ Selection Option Code None Batch Reading rule input ( 01-16 rules) [FIN] [Rules] [FIN] Programming Manual FuzzyScan Batch Reading: When this function is enabled, you can scan multiple barcodes one by one continuously upon one trigger event.
Configure Your FuzzyScan [Code length] Length: 4 byte Specify what length of data output will be acceptable for this symbology. When you calculate the length, you must consider the whole data string which includes the programmed Preamble, Postamble, Scanned Data Length, Prefix/Suffix Symbol ID or AIM ID. Scan the four digit data length from the Option Code. Note: 40 characters is entered as 0040; 9999 is a universal number, indicating all lengths.
Configure Your FuzzyScan You would set up the Batch Reading rule with the following command line: [PROGRAM] [Batch Reading] [0301999941FF07999942FF09999943FF] [FIN] [END] Programming Manual FuzzyScan The breakdown of the command line is shown below: 03 The number of elements in the overall rule 01 Code identifier of Code 128 9999 Code length that must match for Code 128, 9999 = all lengths 41 Start character match for Code 128, 41h = “A” FF End of first code 07 Code identifier of Code 39 999
Configure Your FuzzyScan The breakdown of the command line is shown below: 03 The number of elements in the overall rule 01 Code identifier of Code 128 0010 Code length that must match for Code 128 A-CODE128 sample length (9) plus Suffix Symbol ID (1) = 10 41 Start character match for Code 128, 41h = “A” FF End of first code 07 Code identifier of Code 39 0009 Code length that must match for Code 39 B-CODE39 sample length (8) plus Suffix Symbol ID (1) = 9 Universal matched character, indicating
Configure Your FuzzyScan Operation Control (All Series) ♦ Buzzer, Indicator & Vibrator Control ♦ PROGRAM Family Code Selection P.
Configure Your FuzzyScan Operation Control (All Series) PROGRAM Family Code Selection Dollar Sign Control Redundancy ♦ Dollar Sign, Redundancy & 1D Code Inverse Reading ♦ P.
Configure Your FuzzyScan Operation Control (All Series) ♦ Reread Delay & Good Read Delay Control ♦ PROGRAM Family Code Selection Reread Delay (Double Scan Verification) P.C SS SS SS SS SS SS Parameter Selection Disable Immediate time out Short time out Medium time out Long time out Force verification Programming Manual Option Code 0 1 2 3 4 5 SS None 0 SS 200 msec. 1 SS 500 msec. 2 SS 1 sec. 3 SS 1.5 sec. 4 SS 2 sec. 5 SS 3 sec.
Configure Your FuzzyScan Operation Control (All Series) ♦ Light Source On Time, Hands Free Time-out ♦ PROGRAM Family Code Selection P.
Configure Your FuzzyScan Operation Control (All Series) Programming Manual FuzzyScan PROGRAM ♦ Presentation Auto-Sense & Sensitivity ♦ & Sensitivity Settings ♦ Parameter Selection F_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Condensed DataWizard ♦ Preamble, Postamble, Data Length & Symbol ID Trans. ♦ PROGRAM F_DEFAULT Family Code Selection P.C Preamble SS MS Parameter Selection None 1-15 characters Option Code FIN [00-7F], [FIN] Maximum 15-character input; scan “FIN” to terminate this selection. Postamble SS MS None 1-15 characters FIN [00-7F], [FIN] Maximum 15-character input; scan “FIN” to terminate this selection.
Configure Your FuzzyScan Condensed DataWizard ♦ Data Formatter Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Condensed DataWizard ♦ Data Verifier Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Verifier Control SS MS MS Identified Data Length SS DS Parameter Selection Option Code 2nd Option Code Disable Select one bar code symbology Select all bar code symbologies FIN (2 digits) 00 automatic termination automatic termination Disable Enable FIN (2 digits) Determine the identified data length for verification.
Configure Your FuzzyScan Condensed DataWizard ♦ Data Replacer Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Condensed DataWizard ♦ Data Organizer Setting ♦ Programming Manual FuzzyScan PROGRAM F_DEFAULT Family Code Selection P.
Configure Your FuzzyScan 2D Bar Code Symbology Select a Bar Code Symbology You can select one or all types of bar code symbologies to use Condensed DataWizard for advanced transmission arrangement. If you scan “00” to select all types, the FuzzyScan will arrange all incoming data to meet your pre-defined format. If you want to select only one type bar code, please select one of the option code listed below.
Configure Your FuzzyScan Programming Procedure [Data Verifier] Scan “Program” to enter the programming mode. Scan “Verifier Control” and set bar code symbology to “48” (Interleaved 2 of 5). Application Example If your bar code label is a 16-digit Interleaved 2 of 5 which includes the information of 6-digit date code, 6-digit serial number and 4-digit unit price, you want the FuzzyScan do the following for you without software modification: Scan “Identified Data Length” and set the length to “16”.
Configure Your FuzzyScan [Data Replacer] Scan “Replacer Control” and set bar code symbology to “48”. Scan “1st Replacement” and set the identified position to “00”, then replaced character to “41” (Hex Code of A). [Data Organizer] Scan “Organizer Control” and set bar code symbology to “48”. Scan “1st Organization” and set the identified position to “16”, then set the data transmission to “0” (forward).
Appendix Symbology ID Table Each AIM Code Identifier contains the three-character string ]cm where: ] = Flag Character; c = Code Character; m = Modifier Character 1D Symbology ID Table Cino ID Code Family Primary Format Hex Char. Value UPC UPC-A 2 UPC-A with 2 supple. 32 UPC-A with 5 supple. 42 UPC-E 3 UPC-E with 2 supple. 33 UPC-E with 5 supple. 43 AIM ID Cino ID Code Modified Char. Char.
Appendix 2D Symbology ID Table Cino ID Code Family Primary Format Hex Value QR Code Micro QR Code Programming Manual Cino ID Modified Char. Char. b Q m c d m Japanese Post QR Code Micro QR Code A0 Code Family Code Char. Primary Format Hex AIM ID Char. Value British Post British Post Intelligent Mail barcode Intelligent Mail barcode Code Modified Char. Char.
Appendix Programming Manual FuzzyScan Keyboard Function Code Table No. ANSI ASCII Key Function Ctrl Output No.
Appendix ASCII Input Shortcut To configure the user definable parameters of FuzzyScan via programming menu, FuzzyScan will ask you to scan your desired ASCII value in HEX form. You have to refer to the “HEX/ASCII Table” for details. HEX/ASCII Reference Table H 0 1 2 3 4 5 6 7 0 NUL DLE SPACE 0 @ P ` p Example: 1 SOH DC1 ! 1 A Q a q If you want the scanned data output leading with a Dollar Sign, you have to set the “Preamble” to “$”.
Appendix Host Interface Quick Set RS232 Serial PS/2 (DOS/V) KBW Standard Mode USB HID Standard Mode Keyboard Replacement PS/2 (DOS/V) KBW Turbo Mode USB HID Turbo Mode Programming Manual FuzzyScan USB HID Legacy Mode USB Com Port Emulation 81
Appendix Operation Mode Quick Set (F & L Series) Low Power (Low power trigger) Force (Continued power on) Alternative (Periodic power off) Trigger (External triggering) Toggle (Repeat reading) Programming Manual FuzzyScan Flash (Pulse driven reading) Presentation (Auto sensing) Diagnostic (Test reading) Level (Auto power off) 82
Appendix Operation Mode Quick Set (A Series) Low Power (Low power trigger) Force (Continued power on) Alternative (Periodic power off) Trigger (External triggering) Toggle (Repeat reading) Programming Manual FuzzyScan Level (Auto power off) Presentation (Auto sensing) Diagnostic (Test reading) Multiple Read 83
Appendix Option Codes 0 A 5 F 1 B 6 2 C Programming Manual FuzzyScan 7 3 D 8 4 E 9 FIN (Finish) Abort 84 END (Exit)
Appendix System Commands PROGRAM (Enter Programming Mode) System Information List (SYSLIST) Save User Default FIN (Finish) PowerTool Host Link Programming Manual FuzzyScan User Default END (Exit Programming Mode) Factory Default Master Default Factory Default: After scanning” Factory Default” command, all parameters will be returned to factory default value.
www.cino.com.tw FuzzyScan Family Programming Manual CINO GROUP PC WORTH INT’L CO., LTD.