WIRELESS IMAGER Reference Manual International Edition, Rev.
Wireless FuzzyScan Reference Manual Revision History Rev. No. Released Date Rev.A Oct. 16, 2009 Rev.A1 Oct. 22, 2009 Page 6 Revise “Clone” function operation method. Page 68 Add “Save Configuration” and “Master Default” quick set commands. Rev.A2 Nov. 27, 2009 Rev.A3 Mar. 05, 2010 Rev.A4 Apr. 27, 2010 Page 53 Bluetooth Device Name – Modify user define characters from 1 – 14 characters to 1 – 16 characters. Page 69 Add scanner and cradle indications.
© Copyright Cino Group © Copyright PC Worth Int’l Co., Ltd Cino makes no warranty of any kind with regard to this publication, including, but not limited to, the implied warranty of merchantability and fitness for any particular purpose. Cino shall not be liable for errors contained herein or for incidental consequential damages in connection with the furnishing, performance, or use of this publication. This publication contains proprietary information that is protected by copyright.
Table of Contents Getting Started Getting Familiar with Your FuzzyScan Preparation before Using Decide Your Radio Link Mode Using FuzzyScan in PAIR Mode Using FuzzyScan in PICO Mode Using FuzzyScan in HID Mode Using FuzzyScan in SPP Mode Out-of-range Scanning/Presentation Scanning/Paging Function Batch Scanning (Inventory Mode) 1 2 3 4 5 7 8 10 11 Wireless FuzzyScan Reference Manual Configure Your FuzzyScan Bar Code Programming Manual Programming Procedures Host Interface Selection Symbology Reading Con
Getting Started Getting Familiar with Your FuzzyScan Thank you for choosing Cino FuzzyScan Bluetooth Cordless Image Scanner. Powered by the combination of cutting-edge FuzzyScan 2.0 Imaging Technology and Bluetooth 2.1 EDR wireless technology, it not only provides outstanding reading performance, but also delivers the convenience and freedom of mobility. This document provides a quick reference for installation and operation purposes. The complete documentation is available at www.cino.com.tw.
Getting Started Preparation before Using Install the Battery Ensure the battery contacts of the battery pack are facing the charging contacts inside the battery cavity. Slide the battery pack into the battery cavity until hearing a click sound before locking it with the end cap. The scanner will give 4 beeps when the battery pack is installed properly if the battery pack still has power. Secure the end cap with the screw provided, and make sure the end cap is secured properly before using the scanner.
Getting Started Decide Your Radio Link Mode The FuzzyScan Bluetooth image scanner provides several radio link modes to communicate with most host devices. When the Bluetooth-enabled host device is not available, it can work with the smart cradle in PAIR mode (one to one connection) or PICO mode (multiple connections) to provide a plug-and-play cordless migration of your existing non-Bluetooth-enabled IT assets.
Getting Started Using FuzzyScan in PAIR Mode Ensure the battery is fully charged. You may refer to the section of Preparations before Using for details. Please choose your desired interface cable, then plug it into the host interface port of the smart cradle and connect it to the host device. USB PS/2 RS232 Turn on the power of your host device. Please note that the scanner has been pre-paired already, if the scanner is shipped together with the smart cradle.
Getting Started Using FuzzyScan in PICO Mode Ensure the battery is fully charged and choose your desired interface cable, then plug it into the host interface port of the smart cradle and connect it to the host device. USB PS/2 RS232 Turn on the power of your host device. Ensure the side indicators of the smart cradle give alternative red and green blinks (in “Uninstall” state).
Getting Started Clone Function For the user’s convenience, the clone function will help you to clone the host interface related parameters (please refer to following table for details) from one of the paired scanners to the rest of paired scanners under PICO mode. You can use one of the paired scanners to set the host interface related parameters first and then scan “Save Configuration” command.
Getting Started Using FuzzyScan in HID Mode Ensure the battery is fully charged. Power on the scanner within radio range and ensure the status indicator of scanner gives alternating red and green blinks (in “Uninstall” state). If the scanner is not in uninstall state, please scan the “Uninstall” command first. Then scan the “HID Mode” command, and the link indicator of scanner will give 3 blue blinks per 2 seconds.
Getting Started Using FuzzyScan in SPP Mode Establish SPP Master Connection Ensure the battery is fully charged. Please go to the folder of “Hardware” located in Bluetooth Advanced Setting of the remote host device to check its device MAC address. Then prepare a 12-character Code 128 barcode of the remote host device MAC address, or follow the step 4 to input MAC address by scanning 12 option codes. Ensure a virtual COM port is available in your remote host for connecting the scanner.
Getting Started Establish SPP Slave Connection Ensure the battery is fully charged and a virtual COM port is available in your remote host for connecting the scanner. If not, please go to the folder of “Client Applications” located in Bluetooth Advanced Setting. Click the “Add COM Port” to add one more Bluetooth COM port. Power on the scanner within radio range and ensure the status indicator of scanner gives alternating red and green blinks (in “Uninstall” state).
Getting Started Out-of-range Scanning When the radio is connected between the scanner and the remote host device, the scanner will transmit each scanned data right after scanning the barcode. However, the scanner is preset for unable to scan any barcode data when it loses the radio connection with the remote host device. If you enable the out-of-range scanning function, the scanner is able to continue scanning barcode data while it is out of working range.
Getting Started Batch Scanning (Inventory Mode) Thanks to the specially designed Batch Scanning function, the scanner is capable of storing the barcode data up to 20,000 EAN-13 labels. It is an ideal cost-saving solution for inventory applications. Once you scan the “Enter Batch Scanning” command to activate this function, all scanned barcode data will be stored into the memory storage, and the status indicator of scanner will give green blink at regular interval during batch scanning.
Getting Started Auto Delete Stored Data after Transmission Keep Stored Data after Transmission ◆ If you scanned a wrong barcode, the “Delete Last Scanned Data’’ command is helpful to recover mistake. By scanning the ‘’Delete Last Scanned Data’’ command, the last stored data can be deleted.
Configure Your FuzzyScan Bar Code Programming Menu The FuzzyScan bar code commands are specially designed Proprietary bar code labels which allow you to set the FuzzyScan internal programming parameters. There are System Command, Family Code and Option Code for programming purpose. Wireless FuzzyScan Reference Manual Each programmable family and bar code command label is listed on the same page with major system commands.
Configure Your FuzzyScan If the programming family must take multiple scans selection, cycling scan selection, or dual level selection procedures, the family of the programming menu will be marked with the matched representing symbol of Programming Category (P.C.) in bold font listed in the following table. You can easily find the bold mark in the programming menu, and refer to their flowcharts for details.
Configure Your FuzzyScan Program & End System List, Group & Master Default Scan “PROGRAM” Scan “SYSLIST” FuzzyScan will enter programming mode, and inhibit all non-programming functions. FuzzyScan will list the product information and revision number to host via selected host interface, Wireless FuzzyScan Reference Manual then issue the completion beeping.
Configure Your FuzzyScan Single scan selection Multiple scans selection Scan Scan “PROGRAM” Scan One of Family Codes “PROGRAM” Enter programming mode. Select one of desired Scan One of Family Codes programming families. Select one of desired programming families. 1. Select one or several Select one option code of Scan One of Option Codes Enter programming mode. Scan One or Several Option Codes desired parameter. option codes to select desired parameters. 2.
Configure Your FuzzyScan Cycling scan selection Dual level selection Scan “PROGRAM” Scan One of Family Codes Scan “PROGRAM” Enter programming mode. Select one of desired Scan One of Family Codes programming families. Cycling select one or Scan One of Option Codes (1st) Scan Several Option Codes several option codes of desired parameters as “Single” or “Multiple” (2nd) Scan One or Several Option Codes Wireless FuzzyScan Reference Manual Scan “FIN” Repeat Selection programming families.
Configure Your FuzzyScan Host Interface Selection Wireless FuzzyScan Reference Manual PROGRAM F_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Symbology Reading Control ♦ User Defined Symbol ID ♦ Wireless FuzzyScan Reference Manual PROGRAM F_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Symbology Reading Control ♦ Symbology ID Transmission ♦ Wireless FuzzyScan Reference Manual PROGRAM F_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Symbology Reading Control ♦ Readable Bar Code Setting ♦ PROGRAM Family Code Selection P.C Readable Symbology Setting SS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS CS Remember to scan “FIN” to terminate this selection. But if you select the Reference Manual “ Auto ”, FuzzyScan will terminate this Wireless FuzzyScan F_DEFAULT selection automatically.
Configure Your FuzzyScan Symbology Reading Control ♦ Code 39/Code 32 Setting ♦ Wireless FuzzyScan Reference Manual PROGRAM F_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Symbology Reading Control ♦ Codabar/NW-7 Setting ♦ Wireless FuzzyScan Reference Manual PROGRAM F_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Symbology Reading Control ♦ UPC-A & UPC-E Setting ♦ Wireless FuzzyScan Reference Manual PROGRAM F_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Symbology Reading Control ♦ UPC-A & UPC-E Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Symbology Reading Control ♦ EAN Setting ♦ Wireless FuzzyScan Reference Manual PROGRAM F_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Symbology Reading Control ♦ UCC Coupon Extended Code Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Symbology Reading Control ♦ IATA & Interleaved 2 of 5 Setting ♦ Wireless FuzzyScan Reference Manual PROGRAM F_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Symbology Reading Control ♦ Code 25 Family Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection Code 25 Setting SS SS SS SS SS SS SS SS SS SS Disable Standard/Industrial 2 of 5 Enable Standard/Industrial 2 of 5 Disable Matrix 2 of 5 Enable Matrix 2 of 5 Disable China Postal Code Enable China Postal Code Disable check digit verification Enable check digit verification Disable check digit transmission Enable check digit transmission Code 25 Family Min.
Configure Your FuzzyScan Symbology Reading Control ♦ Code 11 & Code 93 Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection Code 11 Setting SS SS SS SS SS SS SS Disable Code 11 Enable Code 11 Disable check digit verification Select 1-check digit verification Select 2-check digit verification Disable check digit transmission Enable check digit transmission Code 11 Min.
Configure Your FuzzyScan Symbology Reading Control ♦ MSI/Plessey Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection MSI/Plessey Setting SS SS SS SS SS SS SS Disable MSI/Plessy Enable MSI/Plessy Select MOD 10 check digit Select MOD 10-10 check digit Select MOD 11-10 check digit Disable check digit transmission Enable check digit transmission MSI/Plessey Min.
Configure Your FuzzyScan Symbology Reading Control ♦ Code 128 & UCC/EAN 128 Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection Code 128/EAN-128 Setting SS SS SS SS SS SS Disable Code 128 and UCC/EAN-128 Enable Code 128 and UCC/EAN-128 Disable function code conversion Enable function code conversion ISBT Concatenation Off ISBT Concatenation On Code 128/EAN-128 Min.
Configure Your FuzzyScan Symbology Reading Control ♦ UK/Plessey Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection UK/Plessey Setting SS SS SS SS SS SS SS SS Disable UK/Plessey Enable UK/Plessey Select UK/Plessey Standard Format Select UK/Plessey CLSI Format Disable Convert X to A-F Enable Convert X to A-F Disable check digit transmission Enable check digit transmission UK/Plessey Min.
Configure Your FuzzyScan Symbology Reading Control ♦ Telepen Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection Telepen Setting SS SS SS SS SS SS Disable Telepen Enable Telepen Select Telepen Numeric mode Select Telepen Full ASCII mode Disable check digit transmission Enable check digit transmission Telepen Min.
Configure Your FuzzyScan Symbology Reading Control ♦ GS1 DataBar Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection GS1 DataBar Setting SS SS SS SS SS SS Disable GS1 DataBar (RSS-14) Enable GS1 DataBar (RSS-14) Disable GS1 DataBar Limited Enable GS1 DataBar Limited Disable GS1 DataBar Expanded Enable GS1 DataBar Expanded GS1 DataBar Min. Length SS MS Default (04) 01-Maximum Option Code 0 1 2 3 4 5 FIN (2 digits) Only available for Expanded GS1 Databar.
Configure Your FuzzyScan Symbology Reading Control ♦ Linear-stacked & Korea Post Code Setting ♦ Wireless FuzzyScan Reference Manual PROGRAM F_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Keyboard Interface Control ♦ Keyboard Layout (Language) Setting ♦ Wireless FuzzyScan Reference Manual PROGRAM F_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Keyboard Interface Control ♦ Record Suffix, Preamble, Postamble & Caps Lock ♦ PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection Record Suffix SS SS SS SS SS SS None RETURN TAB SPACE ENTER (Numeric Key Pad) User defined character (1 character) Preamble SS MS None 1-15 characters Option Code 0 1 2 3 4 5, (00-7F) FIN [00-7F], [FIN] Maximum 15-character input; scan “FIN” to terminate this selection.
Configure Your FuzzyScan Keyboard Interface Control ♦ Delay Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Intermessage Delay SS MS Parameter Selection None 1-99 (x10) msec. Option Code FIN (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. Intercharacter Delay SS MS None 1-99 (x5) msec. FIN (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
Configure Your FuzzyScan Keyboard Interface Control ♦ Emulation Setting & Upper/Lower Case Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Function Key Emulation SS SS Parameter Selection Enable ASCII 00-31 code as keyboard function code output Ctrl-Output Option Code 0 1 Wireless FuzzyScan Reference Manual Refer to Appendix – Keyboard Function Code Table for details.
Configure Your FuzzyScan Serial Interface Control ♦ Record Suffix, Preamble ,Postamble Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C STX/ETX Control SS SS Parameter Selection Option Code Disable STX/ETX transmission Enable STX/ETX transmission 0 1 STX/ETX are two characters used to indicate the starting and ending of the total data frame transmitted via serial interface.
Configure Your FuzzyScan Serial Interface Control ♦ Delay Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Intermessage Delay SS MS Parameter Selection None 1-99 (x10) msec. Option Code FIN (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. Intercharacter Delay SS MS None 1-99 (x5) msec. FIN (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
Configure Your FuzzyScan Serial Interface Control ♦ Protocol, Baud Rate, Data Frame & Time Out Setting ♦ Wireless FuzzyScan Reference Manual PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection Option Code Handshaking Protocol SS SS SS SS None (free running mode) RTS/CTS (hardware handshaking) ACK/NAK (software handshaking) Xon/Xoff (software handshaking) Baud Rate (BPS) SS SS SS SS SS 38.4K BPS 19.2K BPS 9600 BPS 4800 BPS 2400 BPS 1200 BPS 600 BPS 300 BPS 57.6K BPS 115.
Configure Your FuzzyScan Wand/Laser Emulation Control ♦ Output Polarity, Signal State, Margin/Module Time, etc. ♦ PROGRAM F_DEFAULT Family Code Selection P.C Output Polarity SS SS Parameter Selection Option Code High level (5Vdc) on Bar (low level on Space) Low level (0Vdc) on Bar (high level on Space) 0 1 Determine the output voltage level for both bar and space.
Configure Your FuzzyScan Operation Control ♦ Operation Mode ♦ PROGRAM F_DEFAULT Family Code Selection P.C Operation Mode SS SS Parameter Selection Trigger mode Presentation mode Option Code 1 2 Wireless FuzzyScan Reference Manual Trigger Mode (External Triggering) The scanner goes into standby state after scanning the bar code. You must press the trigger to turn on the light source of the scanner before scanning the bar code.
Configure Your FuzzyScan Operation Control ♦ Buzzer, Indicator, Vibrator, Inverse Reading, Dollar Sign ♦ PROGRAM F_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Operation Control ♦ Flash Duty Cycle, Redundancy, Delay Setting ♦ PROGRAM Family Code Selection P.C Flash Duty Cycle SS SS SS SS 1/2 duty cycle 2/3 duty cycle 3/4 duty cycle 4/5 duty cycle 0 1 2 3 Redundancy (Scan Voting) SS SS SS SS SS SS None Level 1 Level 2 Level 3 Level 4 Level 5 To prevent potential miss reading.
Configure Your FuzzyScan Operation Control ♦ Time-out Setting, Good Read Beep Duration ♦ Wireless FuzzyScan Reference Manual PROGRAM F_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Operation Control ♦ Presentation Scanning Setting & Scan Rate Adjustment♦ PROGRAM F_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Operation Control ♦ Out-of-range Scanning, Sleep Time-out Control ♦ PROGRAM F_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Operation Control ♦ Batch Scanning Setting ♦ Wireless FuzzyScan Reference Manual PROGRAM F_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Operation Control ♦ Batch Scanning Data Transmission Setting ♦ Wireless FuzzyScan Reference Manual PROGRAM F_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Operation Control ♦ Bluetooth Device Name & Security Setting♦ Wireless FuzzyScan Reference Manual PROGRAM F_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Operation Control ♦ Bluetooth Other Settings ♦ PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection Option Code HID Link Quality Setting SS SS Disable Enable 0 1 Bluetooth Power Saving Mode SS SS Disable Enable 0 1 Wireless FuzzyScan Reference Manual The HID Link Quality Setting While using the HID radio link mode, some errors may occur during the data transmission when the radio link is disconnected.
Configure Your FuzzyScan Condensed DataWizard ♦ Preamble, Postamble, Data Length & Symbol ID Trans. ♦ PROGRAM F_DEFAULT Family Code Selection P.C Preamble SS MS Parameter Selection None 1-15 characters Option Code FIN [00-7F], [FIN] Maximum 15-character input; scan “FIN” to terminate this selection. Postamble SS MS None 1-15 characters FIN [00-7F], [FIN] Maximum 15-character input; scan “FIN” to terminate this selection.
Configure Your FuzzyScan Condensed DataWizard ♦ Data Formatter Setting ♦ PROGRAM Family Code Selection P.
Configure Your FuzzyScan Condensed DataWizard ♦ Data Verifier Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Verifier Control SS MS MS Identified Data Length SS MS Parameter Selection Option Code 2nd Option Code Disable Select one bar code symbology Select all bar code symbologies FIN (2 digits) 00 automatic termination automatic termination Disable Enable FIN (2 digits) Determine the identified data length for verification.
Configure Your FuzzyScan Condensed DataWizard ♦ Data Replacer Setting ♦ PROGRAM Family Code Selection P.
Configure Your FuzzyScan Condensed DataWizard ♦ Data Organizer Setting ♦ PROGRAM Family Code Selection P.
Configure Your FuzzyScan [Data Verifier, Data Replacer, Data Organizer] Select a Bar Code Symbology Wireless FuzzyScan Reference Manual You can select one or all types of bar code symbologies to use Condensed DataWizard for advanced transmission arrangement. If you scan “00” to select all types, the FuzzyScan will arrange all incoming data to meet your pre-defined format. If you want to select only one type bar code, please select one of the option code listed below.
Configure Your FuzzyScan Programming Procedure [Data Verifier] [Data Replacer] Scan “Program” to enter the programming mode. Scan “Verifier Control” and set bar code symbology to “48” (Interleaved 2 of 5). Scan “Identified Data Length” and set the length to “16”. Scan “1st Identified Character” and set the identified position to “00”, then set the identified character to “39” (Hex Code of 9).
Appendix Symbology ID Table Each AIM Code Identifier contains the three-character string ]cm where: ] = Flag Character c = Code Character m = Modifier Character Cino ID Code Family Primary Format AIM ID Code Code Modified Character Character Character UPC-A UPC-A with 2 supple. A UPC-A with 5 supple. UPC E UPC-E UPC-E with 2 supple. Cino ID E EAN/JAN-8 1 EAN/JAN-8 with 2 supple. 2 EAN/JAN-8 with 5 supple.
Appendix Wireless FuzzyScan Reference Manual Keyboard Function Code Table No. ANSI ASCII 00 NUL 00H 01 SOH 02 Key Function No.
Appendix ASCII Input Shortcut To configure the user definable parameters of FuzzyScan via programming menu, FuzzyScan will ask you to scan your desired ASCII value in HEX form. You have to refer to the “HEX/ASCII Table” for details. 1 2 3 4 5 6 7 0 NUL DLE SPACE 0 @ P ` p Example: 1 SOH DC1 ! 1 A Q a q If you want the scanned data output leading with a Dollar Sign, you have to set the “Preamble” to “$”. The configuration procedure is listed below for reference.
Appendix Link Mode Quick Set Uninstall SPP Slave Mode PAIR Mode HID Mode SPP Master Mode PICO Mode Wireless FuzzyScan Reference Manual Operation Mode Quick Set Trigger Mode Presentation Mode 65
Appendix Host Interface Quick Set (Work with Smart Cradle only) RS232 Serial PS/2 (DOS/V) KBW Standard Mode USB HID Standard Mode Keyboard Replacement PS/2 (DOS/V) KBW Turbo Mode USB HID Turbo Mode Wireless FuzzyScan Reference Manual USB Com Port Emulation 66
Appendix Option Codes 0 8 4 C 1 9 5 D 2 A 6 E Wireless FuzzyScan Reference Manual 3 B 7 F FIN (Finish) END (Exit) 67
Appendix System Commands PROGRAM (Enter Programming Mode) Save Configuration Sleep FIN (Finish) Clone Paging END (Exit Programming Mode) Factory Default Wireless FuzzyScan Reference Manual PowerTool Host Link System Information List (SYSLIST) Master Default Factory Default: After scanning” Factory Default” command, all parameters will be returned to factory default value (The radio link will be disconnected and the scanner will revert to uninstall state).
Appendix Indications Link Indicator Wireless FuzzyScan Reference Manual Status Indicator Descriptions Radio connected Link Indicator 1 blue blink per 2.5 sec. Beeper Off Radio disconnected 3 blue blinks per 2 sec. Off During connection Quick blue blinks Short clicks Radio connection built 1 blue blink per 2.5 sec. 4 beeps in ascending tone Radio connection lost 3 blue blinks per 2 sec.
Appendix Center Indicator Side Indicators HB2100 Charging Cradle Indication Descriptions Power on Power Beeper Steady blue Off HB2110 Smart Cradle Indications Wireless FuzzyScan Reference Manual Descriptions Indicators Beeper Power on Center 1 blue blink Off Power on beeps Smart Cradle Upgrade State Off Steady red Short clicks Uninstall state Off Alternative red-green blinks Off Steady blue Steady Green Off Radio Disconnected Off Steady red Off Radio Connected Off Off Radio
FuzzyScan Wireless Reference Manual CINO GROUP PC WORTH INT’L CO., LTD. www.cino.com.