WIRELESS IMAGER Reference Manual International Edition, Rev.
Revision History Rev. No. Released Date Rev. A Oct 16, 2009 Rev. A1 Oct 22, 2009 Rev. A2 Rev. A3 Description First Release Page 6 Page 68 Revise “Clone Function” operation method. Add “Save Configuration” and “Master Default” to System Commands. Page 53 Page 69 “Bluetooth Device Name” – Modify user define characters from 1 – 14 characters to 1 – 16 characters. Add “Indications”. Page 25 Page 43 Page 45 Page 48 Modify UPC-E/EAN-8 expansion and UPC-A standardization.
Revision History Rev. No. Released Date Page 48 Remove ”Scan Voting” and add “Scan Rate Control ” Rev. A6 Sep 20, 2010 Page 54 Add “” parameter selection in Batch Data Quantity Output Format. Rev. A7 Nov 10, 2010 Page 44 Baud Rate – Cancel Baud Rate 300/600 BPS. Page 47 Rev. A8 Jan 2, 2011 Buzzer Tone Adjust – Modify No power-on beep behavior. The setting of No power-on beep will impact both Bluetooth Scanner and Smart Cradle.
Revision History Rev. No. Released Date Rev. B3 Nov 04, 2011 Rev. B4 Jan 03, 2012 Description Page 3, 5, 10 “Paging/ Reset button” is changed from 3 seconds to 5 seconds. Page 24 Add a new function “Codabar Check Digit Settings” Page 49 Cancel 1 parameter of “Code 39/Code 128 Emulation”.(Disable standard cod 39 emulation - -0) Page 49 Change of default setting to Enable standard code 39 skip emulation in “Code 39/ Code 128 Emulation”.
Revision History Rev. No. Released Date Description Support 1D Pocket Scanner Rev. C2 Reference Manual Page 21: Add “USB EFT Terminal Mode” for “Host Interface Selection”. Page 96 add “USB HID Legacy Mode” Host Interface Quick Set Command. Page 97 Add “Abort” Quick Set Command Rev. C3 May 09, 2014 Page 16 Add “Clear All Scanned Data” Command. Rev. C4 Feb.
© Copyright PC Worth Int’l Co., Ltd Cino makes no warranty of any kind with regard to this publication, including, but not limited to, the implied warranty of merchantability and fitness for any particular purpose. Cino shall not be liable for errors contained herein or for incidental consequential damages in connection with the furnishing, performance, or use of this publication. This publication contains proprietary information that is protected by copyright. All rights are reserved.
LP0002 MIC T401 LED Eye Safety IEC62471 Exempt group Wireless FuzzyScan Reference Manual Laser Eye Safety IEC60825-1 Class 1
Table of Contents Getting Started Getting Familiar with Your FuzzyScan Preparation before Using Decide Your Radio Link Mode Use FuzzyScan in PAIR Mode Use FuzzyScan in PICO Mode Use FuzzyScan in HID Mode Use FuzzyScan in SPP Mode Out-of-range Scanning/Presentation Scanning/Sleep Mode & Power Off Batch Scanning (Inventory Mode) 1 3 5 6 7 9 10 12 14 Wireless FuzzyScan Reference Manual Configure Your FuzzyScan Bar Code Programming Manual Programming Procedures Host Interface Selection Symbology Reading Con
Getting Started Getting Familiar with Your FuzzyScan Thank you for choosing Cino FuzzyScan Bluetooth Cordless Image Scanner. Powered by the combination of cutting-edge FuzzyScan Imaging Technology and Bluetooth wireless technology, it not only provides outstanding reading performance, but also delivers the convenience and freedom of mobility. It’s ideal for a broad range of applications to unleash your productivity with ease. This document provides a quick reference for installation and operation.
Getting Started Px680BT Scanner Status Indicator Power/Link Indicators Reserved Function Key 1 Function Key 2 Reserved Trigger Battery Cover Reset Key Micro USB Port Wireless FuzzyScan Reference Manual Scan Window Central Indicator Side Indicators (HB3112 only) USB Bus Power Switch Mounting Holes DC Power Jack Paging/Reset Key Host Interface Port (HB3112) USB Port (HB3100) 2
Getting Started Preparation before Using – Gun type Scanners Install the Battery Ensure the battery contacts of the battery pack are facing the charging contacts inside the battery cavity. Slide the battery pack into the battery cavity until hearing a click sound before locking it with the end cap. The scanner will give 4 beeps when the battery pack is installed properly if the battery pack still has power. Secure the end cap with the screw provided.
Getting Started Preparation before Using – Pocket Scanners Install the Battery Take off the battery cover from the scanner by removing two blue tapes. Ensure the battery contacts of the battery pack are facing the charging contacts inside the battery cavity. Then click the battery pack into the battery cavity carefully. Place the battery cover in the right orientation onto the back of the scanner.
Getting Started Decide Your Radio Link Mode The FuzzyScan Bluetooth image scanner provides several radio link modes to communicate with most host devices. When the Bluetooth-enabled host device is not available, it can work with the smart cradle in PAIR mode (peer-to-peer connection) or PICO mode (multiple connections) to provide a plug-and-play cordless migration of your existing non-Bluetooth-enabled devices.
Getting Started Use FuzzyScan in PAIR Mode Ensure the battery is fully charged. You may refer to the section of Preparations before Using for details. Please choose your desired interface cable, then plug it into the host interface port of the smart cradle and connect it to the host device. USB PS/2 RS232 Turn on the power of your host device. Power on or wake up the scanner by pressing the Trigger key if the scanner is power-off or in sleep state.
Getting Started Use FuzzyScan in PICO Mode Ensure the battery is fully charged and choose your desired interface cable, then plug it into the host interface port of the smart cradle and connect it to the host device. USB PS/2 RS232 Turn on the power of your host device. Ensure the side indicators of the smart cradle blink red and green alternatively (in “Uninstall” state).
Getting Started Clone Function For the user’s convenience, the clone function will help you to clone the host interface related parameters (please refer to following table for details) from one of the paired scanners to the rest of paired scanners under PICO mode. You can use one of the paired scanners to set the host interface related parameters first and then scan “Save Configuration” command.
Getting Started Use FuzzyScan in HID Mode Ensure the battery is fully charged. Power on the scanner by pressing the Trigger key within radio range if the scanner is power-off or in sleep state, and ensure the status indicator of scanner gives alternative red and green blinks (in “Uninstall” state). If the scanner is not in uninstall state, please scan the “Uninstall” command first.
Getting Started Use FuzzyScan in SPP Mode Establish SPP Master Connection Ensure the battery is fully charged. Please go to the folder “Hardware” located in Bluetooth Advanced Setting of the remote host device to check its device MAC address. Then prepare a 12-character Code 128 barcode of the remote host device MAC address, or follow the step 4 to input MAC address by scanning 12 option codes. Ensure a virtual COM port is available in your remote host for connecting the scanner.
Getting Started Establish SPP Slave Connection Ensure the battery is fully charged and a virtual COM port is available in your remote host for connecting the scanner. If not, please go to the folder “Client Applications” located in Bluetooth Advanced Setting. Click the “Add COM Port” to add one more Bluetooth COM port.
Getting Started Out-of-range Scanning When the radio connection is established between scanner and remote host device, the scanner will transmit each scanned data right after scanning the barcode. However, the scanner is preset not to scan any barcode data when it loses the radio connection with the remote host device. If you enable the out-of-range scanning function, the scanner is able to continue scanning barcode data while it is out of radio coverage.
Getting Started Paging Function The Paging function is helpful for you to locate the paired smart cradle or scanner. If you would like to page the paired smart cradle, you can scan “Paging” command. If you would like to page the paired scanner, you can press the paging/reset button of the smart cradle no longer than 3 seconds.
Getting Started Batch Scanning (Inventory Mode) Thanks to the specially designed Batch Scanning function, the scanner is capable of storing the barcode data. It is an ideal cost-saving solution for inventory applications. Once you scan the ““Enter Batch Scanning” command to activate this function, all scanned barcode data will be stored into the memory storage, and the status indicator of scanner will give green blink at regular interval during batch scanning.
Getting Started There are three ways to output the stored barcode data and quantity information. The preset output format is to transmit stored data as many times as the quantity indicated.But you still can set the scanner to output stored barcode data together with quantity information in two fields, and a preset delimter”,” will be output in between. To fulfill different application requirements, both the delimiter and output sequency can be changed as well.
Getting Started Auto Delete Stored Data after Transmission Keep Stored Data after Transmission ◆ If you scanned a wrong barcode, the “Delete Last Scanned Data’’ command is helpful to recover mistake. By scanning the ‘’Delete Last Scanned Data’’ command, the last stored data can be deleted. If you use pocket scanner, you can also delete the last scanned data by pressing the Function Key 2 twice.
Configure Your FuzzyScan Bar Code Programming Menu The FuzzyScan bar code commands are specially designed Proprietary bar code labels which allow you to set the FuzzyScan internal programming parameters. There are System Command, Family Code and Option Code for programming purpose. Wireless FuzzyScan Reference Manual Each programmable family and bar code command label is listed on the same page with major system commands.
Configure Your FuzzyScan Programming Procedures If the programming family must take multiple scans selection, cycling scan selection, or dual level selection procedures, the family of the programming menu will be marked with the matched representing symbol of Programming Category (P.C.) in bold font listed in the following table. You can easily find the bold mark in the programming menu, and refer to their flowcharts for details.
Configure Your FuzzyScan Program & End System List, Group & Master Default Scan “PROGRAM” Scan “SYSLIST” FuzzyScan will enter programming mode, and inhibit all non-programming functions. FuzzyScan will list the product information and revision number to host via selected host interface, Wireless FuzzyScan Reference Manual then issue the completion beeping.
Configure Your FuzzyScan Single scan selection Multiple scans selection Scan Scan “PROGRAM” “PROGRAM” Enter programming mode. Select one of desired Select one of desired Scan One of Family Codes Scan One of Family Codes programming families. programming families. 1. Select one or several Select one option code of Scan One of Option Codes Enter programming mode. Scan One or Several Option Codes desired parameter. option codes to select desired parameters. 2.
Configure Your FuzzyScan Cycling scan selection Dual level selection Scan “PROGRAM” Scan One of Family Codes Scan “PROGRAM” Enter programming mode. Select one of desired Scan One of Family Codes programming families. Cycling select one or Scan One of Option Codes several option codes of desired parameters as (2nd) Scan One or Several Option Codes Wireless FuzzyScan Reference Manual Scan “FIN” of desired parameters. 1. Select one or several parameters. 2.
Configure Your FuzzyScan Host Interface Selection PROGRAM Family Code Selection F_DEFAULT P.
Configure Your FuzzyScan Symbology Reading Control Wireless FuzzyScan Reference Manual ♦ User Defined Symbol ID ♦ PROGRAM Family Code Selection P.
Configure Your FuzzyScan Symbology Reading Control ♦ User Defined Symbol ID ♦ Wireless FuzzyScan Reference Manual PROGRAM F_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Symbology Reading Control ♦ Symbology ID Transmission ♦ Wireless FuzzyScan Reference Manual PROGRAM F_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Symbology Reading Control ♦ Readable Bar Code Setting ♦ PROGRAM Family Code Selection Readable Symbology Setting Remember to scan “FIN” to terminate this selection. But if you select the “Auto”, FuzzyScan will terminate this Wireless FuzzyScan Reference Manual selection automatically. F_DEFAULT P.
Configure Your FuzzyScan Symbology Reading Control ♦ Readable Bar Code Setting ♦ PROGRAM Family Code Selection F_DEFAULT P.
Configure Your FuzzyScan Symbology Reading Control ♦ Code 39/Code 32 Setting ♦ Wireless FuzzyScan Reference Manual PROGRAM F_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Symbology Reading Control ♦ Code 39 Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Code 39 Security Level SS SS SS SS Parameter Selection Option Code 0 1 2 3 Level 0 Level 1 Level 2 Level 3 Wireless FuzzyScan Reference Manual Code 39 Security Level The scanner offers four levels of decode security for Code39 bar codes: Level 0: If you are experiencing misread of poorly-printed or serious out-of-spec. bar codes in level 1, please select level 0.
Configure Your FuzzyScan Symbology Reading Control ♦ Codabar/NW-7 Setting ♦ Wireless FuzzyScan Reference Manual PROGRAM F_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Symbology Reading Control ♦ Codabar/NW-7 Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Codabar Max. Length SS MS Parameter Selection Default (98) 98-Minimum FIN (2 digits) Reference Manual Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
Configure Your FuzzyScan Symbology Reading Control ♦ UPC-A & UPC-E Setting ♦ Wireless FuzzyScan Reference Manual PROGRAM F_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Symbology Reading Control ♦ UPC-A & UPC-E Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Symbology Reading Control ♦ EAN Setting ♦ Wireless FuzzyScan Reference Manual PROGRAM F_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Symbology Reading Control ♦ EAN Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Symbology Reading Control ♦ UCC Coupon Extended Code Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C UCC Coupon Extended Code SS SS Parameter Selection Disable UCC Coupon Extended Code Enable UCC Coupon Extended Code Option Code 0 1 Wireless FuzzyScan Reference Manual UCC Coupon Extended Code When UCC coupon extended code function is enabled, scanner decodes UPC-A barcodes starting with digit “5”, EAN-13 barcodes starting with digit “99” and GS1-128 Coupon Codes.
Configure Your FuzzyScan Symbology Reading Control ♦ IATA & Interleaved 2 of 5 Setting ♦ Wireless FuzzyScan Reference Manual PROGRAM F_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Symbology Reading Control ♦ Code 25 Family Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection Code 25 Setting SS SS SS SS SS SS SS SS SS SS Disable Standard/Industrial 2 of 5 Enable Standard/Industrial 2 of 5 Disable Matrix 2 of 5 Enable Matrix 2 of 5 Disable China Postal Code Enable China Postal Code Disable check digit verification Enable check digit verification Disable check digit transmission Enable check digit transmission Code 25 Family Min.
Configure Your FuzzyScan Symbology Reading Control ♦ Code 11 & Code 93 Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection Code 11 Setting SS SS SS SS SS SS SS Disable Code 11 Enable Code 11 Disable check digit verification Select 1-check digit verification Select 2-check digit verification Disable check digit transmission Enable check digit transmission Code 11 Min.
Configure Your FuzzyScan Symbology Reading Control ♦ MSI/Plessey Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection MSI/Plessey Setting SS SS SS SS SS SS SS Disable MSI/Plessy Enable MSI/Plessy Select MOD 10 check digit Select MOD 10-10 check digit Select MOD 11-10 check digit Disable check digit transmission Enable check digit transmission MSI/Plessey Min.
Configure Your FuzzyScan Symbology Reading Control ♦ Code 128 Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection Code 128 Setting SS SS SS SS Disable Code 128 and GS1-128 Enable Code 128 and GS1-128 ISBT Concatenation Off ISBT Concatenation On Code 128 Min. Length SS MS Default (01) 01-Maximum Option Code 0 1 2 3 FIN (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. Code 128 Max.
Configure Your FuzzyScan Symbology Reading Control ♦ GS1-128 Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection GS1-128 Setting SS SS Disable GS1-128 Enable GS1-128 GS1-128 Min. Length SS MS Default (01) 01-Maximum Option Code 0 1 FIN (2 digits) Scan 2 digits from the option code chart in Appendix; then FuzzyScan will terminate this selection automatically. GS1-128 Max.
Configure Your FuzzyScan Symbology Reading Control ♦ UK/Plessey Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection UK/Plessey Setting SS SS SS SS SS SS SS SS Disable UK/Plessey Enable UK/Plessey Select UK/Plessey Standard Format Select UK/Plessey CLSI Format Disable Convert X to A-F Enable Convert X to A-F Disable check digit transmission Enable check digit transmission UK/Plessey Min.
Configure Your FuzzyScan Symbology Reading Control ♦ Telepen Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection Telepen Setting SS SS SS SS SS SS Disable Telepen Enable Telepen Select Telepen Numeric mode Select Telepen Full ASCII mode Disable check digit transmission Enable check digit transmission Telepen Min.
Configure Your FuzzyScan Symbology Reading Control ♦ GS1 DataBar Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection GS1 DataBar Setting SS SS SS SS SS SS Disable GS1 DataBar (RSS-14) Enable GS1 DataBar (RSS-14) Disable GS1 DataBar Limited Enable GS1 DataBar Limited Disable GS1 DataBar Expanded Enable GS1 DataBar Expanded GS1 DataBar Min. Length SS MS Default (04) 01- Maximum Option Code 0 1 2 3 4 5 FIN (2 digits) Only available for Expanded GS1 Databar.
Configure Your FuzzyScan Symbology Reading Control ♦ Composite Codes, Codablock F PDF417/MicroPDF417 & Setting ♦ PROGRAM Family Code Selection P.C Composite Codes Setting SS SS SS SS Parameter Selection Disable composite codes Enable composite codes UPC Composite Mode: UPC never linked UPC Composite Mode: UPC always linked F_DEFAULT Option Code 0 1 2 3 If UPC Composite Mode: UPC never linked is selected, UPC barcodes are transmitted whether MicroPDF417 symbol is detected or not.
Configure Your FuzzyScan Symbology Reading Control ♦ Code 16K & Code 49 Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection Code 16K Setting SS SS Disable Code 16K Enable Code 16K Code 16K Min. Length SS MS Default (01) 01-Maximum Option Code 0 1 FIN (3 digits) Scan 3 digits from the option code chart in Appendix; then FuzzyScan will terminate this selection automatically. Code 16K Max.
Configure Your FuzzyScan Symbology Reading Control ♦ QR Code Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C QR Code Setting SS SS QR Code Min.
Configure Your FuzzyScan Symbology Reading Control ♦ Data Matrix Setting ♦ PROGRAM 11Family Code Selection Data Matrix Setting Data Matrix Min. Length F_DEFAULT P.
Configure Your FuzzyScan Symbology Reading Control ♦MaxiCode Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C MaxiCode Setting SS Disable MaxiCode 0 SS Enable MaxiCode 1 SS MS Default (01) 01-Maximum MaxiCode Min. Length Parameter Selection Option Code FIN (3 digits) Scan 3 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. MaxiCode Max.
Configure Your FuzzyScan Symbology Reading Control ♦ Aztec Code Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection Aztec Code Setting SS SS Disable Aztec Code Enable Aztec Code Aztec Code Min. Length SS MS Default (01) 01-Maximum Option Code 0 1 FIN (4 digits) Scan 4 digits from the option code chart in Appendix; then FuzzyScan will terminate this selection automatically. Aztec Code Max.
Configure Your FuzzyScan Symbology Reading Control ♦ Australian Post, US Planet, US Postnet, British Post & Japan Post Setting ♦ Wireless FuzzyScan Reference Manual PROGRAM Parameter Selection F_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Symbology Reading Control ♦ Netherlands KIX Code, Intelligent Mail & Korea Post Code Setting ♦ Wireless FuzzyScan Reference Manual PROGRAM Parameter Selection F_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Keyboard Interface Control ♦ Keyboard Layout (Language) Setting ♦ Wireless FuzzyScan Reference Manual PROGRAM F_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Keyboard Interface Control ♦ Record Suffix, Preamble, Postamble, FNC1 Transmit & Caps Lock ♦ PROGRAM Family Code Selection P.C Parameter Selection Record Suffix SS SS SS SS SS SS None RETURN TAB SPACE ENTER (Numeric Key Pad) User defined character (1 character) Preamble SS MS None 1-15 characters F_DEFAULT Option Code 0 1 2 3 4 5, (00-7F) FIN [00-7F], [FIN] Maximum 15-character input; scan “FIN” to terminate this selection.
Configure Your FuzzyScan Wireless FuzzyScan Reference Manual FNC1 Symbol Char. Transmit: When this function is enabled and the FNC1 is contained in scanned data, the scanner transmits the FNC1 to the host. Chart of theFNC1 is provided in Appendix- Keyboard Function Code Table. When the scanner interface is set to keyboard, the scan code is converted to corresponding key function before it is transmitted.
Configure Your FuzzyScan Keyboard Interface Control ♦ Delay Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Intermessage Delay SS MS Parameter Selection None 1-99 (x10) msec. Option Code FIN (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. Intercharacter Delay SS MS None 1-99 (x5) msec. FIN (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
Configure Your FuzzyScan Keyboard Interface Control ♦ Emulation Setting, Key Pad Emulation & Upper/Lower Case Setting ♦ PROGRAM Family Code Selection P.C Function Key Emulation SS SS Parameter Selection Enable ASCII 00-31 code as keyboard function code output Ctrl-Output F_DEFAULT Option Code 0 1 Wireless FuzzyScan Reference Manual Refer to Appendix – Keyboard Function Code Table for details.
Configure Your FuzzyScan Serial Interface Control ♦ Record Suffix, Preamble ,Postamble Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C STX/ETX Control SS SS Parameter Selection Option Code Disable STX/ETX transmission Enable STX/ETX transmission 0 1 STX/ETX are two characters used to indicate the starting and ending of the total data frame transmitted via serial interface.
Configure Your FuzzyScan Serial Interface Control ♦ Delay Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Intermessage Delay SS MS Parameter Selection None 1-99 (x10) msec. Option Code FIN (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically. Intercharacter Delay SS MS None 1-99 (x5) msec. FIN (2 digits) Scan 2 digits from the option code chart in Appendix, then FuzzyScan will terminate this selection automatically.
Configure Your FuzzyScan Serial Interface Control ♦ Protocol, ACK/NAK Setting ♦ Wireless FuzzyScan Reference Manual PROGRAM F_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Serial Interface Control ♦Time Out Setting, Baud Rate, Data Frame ♦ Wireless FuzzyScan Reference Manual PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection Option Code Serial Response Time-out SS SS SS SS SS SS None 200 mseconds 500 mseconds 800 mseconds 1 second 2 seconds 3 seconds 4 seconds 5 seconds 8 seconds 10 seconds 15 seconds 0 1 2 3 4 5 6 7 8 9 A B Baud Rate (BPS) SS SS SS SS 38.4K BPS 19.2K BPS 9600 BPS 4800 BPS 2400 BPS 1200 BPS 57.
Configure Your FuzzyScan Wand/Laser Emulation Control (F, L, PF & PL Series) [ PROGRAM Family Code Selection Output Polarity ♦ Output Polarity, Signal State, Margin/Module Time ♦ P.C SS SS Parameter Selection High level (5Vdc) on Bar (low level on Space) Low level (0Vdc) on Bar (high level on Space) F_DEFAULT Option Code 0 1 Determine the output voltage level for both bar and space.
Configure Your FuzzyScan Wand/Laser Emulation Control (F, L, PF & PL Series) PROGRAM Family Code Selection ♦ Output Polarity, Signal State, Margin/Module Time ♦ P.
Configure Your FuzzyScan Operation Control ♦ Operation Mode ♦ PROGRAM F_DEFAULT Family Code Selection P.C Operation Mode SS SS Parameter Selection Trigger mode Presentation mode Option Code 1 2 Wireless FuzzyScan Reference Manual Trigger Mode (Low Power Triggering) the scanner goes into standby state after scanning the bar code. You must press the trigger to turn on the light source of the scanner before scanning the bar code.
Configure Your FuzzyScan Operation Control (A Series) ♦ Batch Reading ♦ PROGRAM Family Code Selection P.C Batch Reading SS Parameter Selection None Batch Reading rule input ( 01-16 rules) F_DEFAULT Option Code [FIN] [Rules] [FIN] Batch Reading: When this function is enabled, you can scan multiple barcodes one by one continuously upon one trigger event. The scanner reports a good read beep and indication only if all bar codes set by the “Batch Reading Rule” are read.
Configure Your FuzzyScan [Code length] Length: 4 byte Specify what length of data output will be acceptable for this symbology. When you calculate the length, you must consider the whole data string which includes the programmed Preamble, Postamble, Scanned Data Length, Prefix/Suffix Symbol ID or AIM ID. Scan the four digit data length from the Option Code. Note: 40 characters is entered as 0040; 9999 is a universal number, indicating all lengths.
Configure Your FuzzyScan You would set up the Batch Reading rule with the following command line: [PROGRAM] [Batch Reading] [0301999941FF07999942FF09999943FF] [FIN] [END] Wireless FuzzyScan Reference Manual The breakdown of the command line is shown below: 03 The number of elements in the overall rule 01 Code identifier of Code 128 9999 Code length that must match for Code 128, 9999 = all lengths 41 Start character match for Code 128, 41h = “A” FF End of first code 07 Code identifier of Code
Configure Your FuzzyScan The breakdown of the command line is shown below: 03 The number of elements in the overall rule 01 Code identifier of Code 128 0010 Code length that must match for Code 128 A-CODE128 sample length (9) plus Suffix Symbol ID (1) = 10 41 Start character match for Code 128, 41h = “A” FF End of first code 07 Code identifier of Code 39 0009 Code length that must match for Code 39 B-CODE39 sample length (8) plus Suffix Symbol ID (1) = 9 Universal matched character, indicating
Configure Your FuzzyScan Operation Control (All Series) Wireless FuzzyScan Reference Manual PROGRAM ♦ Buzzer, Indicator, Vibrator, 1D Code Inverse Reading ♦ Parameter Selection F_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Operation Control (All Series) Wireless FuzzyScan Reference Manual PROGRAM ♦ Buzzer, Indicator, Vibrator, 1D Code Inverse Reading ♦ Parameter Selection F_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Operation Control (All Series) ♦ Dollar Sign Control, Redundancy, Control ♦ Wireless FuzzyScan Reference Manual PROGRAM Parameter Selection F_DEFAULT Family Code Selection P.C Dollar Sign Control SS SS SS SS SS Dollar sign output as “ $ “ Dollar sign output as “¥“ Dollar sign output as “ € “ Dollar sign output as “ £ “ Dollar sign output as “ ¢ “ 0 1 2 3 4 Redundancy SS SS SS SS SS SS None Level 1 Level 2 Level 3 Level 4 Level 5 To prevent potential miss reading.
Configure Your FuzzyScan Operation Control (All Series) ♦ Delay Setting ♦ Wireless FuzzyScan Reference Manual PROGRAM Parameter Selection F_DEFAULT Family Code Selection Reread Delay (Double Scan Verification) P.C Option Code SS SS SS SS SS SS Disable Immediate time out Short time out Medium time out Long time out Force verification 0 1 2 3 4 5 Good Read Delay SS SS SS SS SS SS SS None 200 msec. 500 msec. 1 sec. 1.5 sec. 2 sec. 3 sec.
Configure Your FuzzyScan Operation Control (All Series) ♦ Time-out Setting, Good Read Duration ♦ Wireless FuzzyScan Reference Manual PROGRAM Parameter Selection F_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Operation Control (All Series) PROGRAM ♦ Presentation Scanning Setting, Laser Aiming Control ♦ Family Code Selection P.
Configure Your FuzzyScan Operation Control (F, L, PF & PL Series) ♦ Scan Rate Control, ♦ PROGRAM Family Code Selection P.C Scan Rate Control SS SS Parameter Selection Dynamic Fixed F_DEFAULT Option Code 0 1 Wireless FuzzyScan Reference Manual Scan Rate Control: The scanner will have better motion tolerance when you select “Fixed” scan rate. It’s suitable for application which needs higher motion tolerance on the move. But this may impact to the reading distance.
Configure Your FuzzyScan Operation Control (L & PL Series) PROGRAM ♦ Smart stand Power Off Timeout, Laser Aiming Control, LED Illumination Control ♦ Family Code Selection P.C SmartStand Power Off Timeout SS SS SS Parameter Selection 3 mins 5 mins 10 mins F_DEFAULT Option Code 0 1 2 Only available for FuuzzyScan Laser model Laser Aiming Control SS SS Disable Enable 0 1 Only available for L series laser imaging scanner.
Configure Your FuzzyScan Operation Control (A Series) Wireless FuzzyScan Reference Manual PROGRAM ♦ Aiming Control, Delay Aiming & Decode Aiming Control ♦ Parameter Selection F_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Operation Control (A Series) PROGRAM ♦ Center Alignment, Unique Bar Code Reporting ♦ Parameter Selection F_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Operation Control (All Series) PROGRAM ♦ Out-of-range Scanning, Link Supervision Time-out ♦ Parameter Selection F_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Operation Control (All Series) PROGRAM ♦ Sleep Time-out Control, Power Off Time-out Control ♦ Family Code Selection P.
Configure Your FuzzyScan Operation Control (All Series) ♦ Batch Scanning Setting ♦ Wireless FuzzyScan Reference Manual PROGRAM Parameter Selection F_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Operation Control (All Series) ♦ Batch Scanning Data Transmission Setting ♦ Wireless FuzzyScan Reference Manual PROGRAM Parameter Selection F_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Operation Control (All Series) ♦ Bluetooth Device Name & Security Setting♦ Wireless FuzzyScan Reference Manual PROGRAM Parameter Selection F_DEFAULT Family Code Selection P.
Configure Your FuzzyScan Operation Control ♦ Bluetooth Other Settings ♦ PROGRAM F_DEFAULT Family Code Selection P.C Parameter Selection Option Code Bluetooth Power Saving Mode SS SS Disable Enable 0 1 Link Quality Control SS Disable 0 SS Level 1 1 SS Level 2 2 SS Level 3 3 SS Level 4 4 Wireless FuzzyScan Reference Manual The Bluetooth Power Saving Mode Bluetooth module will enter low consumption mode when you enable this function.
Configure Your FuzzyScan Condensed DataWizard ♦ Preamble, Postamble, Data Length & Symbol ID Trans. ♦ PROGRAM F_DEFAULT Family Code Selection P.C Preamble SS MS Parameter Selection None 1-15 characters Option Code FIN [00-7F], [FIN] Maximum 15-character input; scan “FIN” to terminate this selection. Postamble SS MS None 1-15 characters FIN [00-7F], [FIN] Maximum 15-character input; scan “FIN” to terminate this selection.
Configure Your FuzzyScan Condensed DataWizard ♦ Data Formatter Setting ♦ PROGRAM Family Code Selection P.
Configure Your FuzzyScan Condensed DataWizard ♦ Data Verifier Setting ♦ PROGRAM F_DEFAULT Family Code Selection P.C Verifier Control SS MS MS Identified Data Length SS MS Parameter Selection Option Code 2nd Option Code Disable Select one bar code symbology Select all bar code symbologies FIN (2 digits) 00 automatic termination automatic termination Disable Enable FIN (2 digits) Determine the identified data length for verification.
Configure Your FuzzyScan Condensed DataWizard ♦ Data Replacer Setting ♦ PROGRAM Family Code Selection P.
Configure Your FuzzyScan Condensed DataWizard ♦ Data Organizer Setting ♦ PROGRAM Family Code Selection P.
Configure Your FuzzyScan 2D Bar Code Symbology Select a Bar Code Symbology You can select one or all types of bar code symbologies to use Condensed DataWizard for advanced transmission arrangement. If you scan “00” to select all types, the FuzzyScan will arrange all incoming data to meet your pre-defined format. If you want to select only one type bar code, please select one of the option code listed below.
Configure Your FuzzyScan Application Example Programming Procedure If your bar code label is a 16-digit Interleaved 2 of 5 which includes the information of 6-digit date code, 6-digit serial number and 4-digit unit price, you want the FuzzyScan do the following for you without software modification: [Data Verifier] Apply only Interleaved 2 of 5 to the condensed DataWizard. Check bar code is actually with 16-digit length. Allow bar code output whose date code is leading with “9”.
Configure Your FuzzyScan [Data Replacer] Scan “Replacer Control” and set bar code symbology to “48”. Scan “1st Replacement” and set the identified position to “00”, then replaced character to “41” (Hex Code of A). [Data Organizer] Scan “Organizer Control” and set bar code symbology to “48”. Scan “1st Organization” and set the identified position to “16”, then set the data transmission to “0” (forward).
Appendix Symbology ID Table Each AIM Code Identifier contains the three-character string ]cm where: ] = Flag Character, c = Code Character, m = Modifier Character Cino ID Code Family Primary Format Hex value UPC-A UPC AIM ID Code Code Chara Charact cter er 2 UPC-A with 2 supple. 32 UPC-A with 5 supple. 42 UPC-E 3 UPC-E with 2 supple. 33 UPC-E with 5 supple.
Appendix 2D Symbology ID Table Cino ID Code Family Primary Format Hex Value QR Code Micro QR Code Reference Manual Cino ID Code Family Code Modified Char. Char. b Q m c d m Japanese Post Char. Micro QR Code Hex Char. Value QR Code A0 Primary Format AIM ID British Post British Post Intelligent Mail barcode Intelligent Mail barcode Code Modified Char. Char.
Appendix Wireless FuzzyScan Reference Manual Keyboard Function Code Table No. ANSI ASCII 00 NUL 00H 01 SOH 02 Key Function No.
Appendix ASCII Input Shortcut To configure the user definable parameters of FuzzyScan via programming menu, FuzzyScan will ask you to scan your desired ASCII value in HEX form. You have to refer to the “HEX/ASCII Table” for details. 1 2 3 4 5 6 7 0 NUL DLE SPACE 0 @ P ` p Example: 1 SOH DC1 ! 1 A Q a q If you want the scanned data output leading with a Dollar Sign, you have to set the “Preamble” to “$”. The configuration procedure is listed below for reference.
Appendix Link Mode Quick Set PAIR Mode PICO Mode Uninstall SPP Master Mode SPP Slave Mode HID Mode Wireless FuzzyScan Reference Manual HID Legacy Mode HID Mode with Passkey 98
Appendix Host Interface Quick Set (Work with Smart Cradle only) USB HID Standard Mode PS/2 (DOS/V) KBW Standard Mode RS232 Serial USB HID Turbo Mode PS/2 (DOS/V) KBW Turbo Mode USB Com Port Emulation Wireless FuzzyScan Reference Manual USB HID Legacy Mode PS/2 (DOS/V) Keyboard Replacement 99
Appendix Option Codes 0 8 4 C 1 9 5 D 2 A 6 E Wireless FuzzyScan Reference Manual 3 B 7 FIN (Finish) F Abort 100 END (Exit)
Appendix Connecting Apple iOS Devices Quick Sets Enable Variable PIN Code Disable Variable PIN Code BT PIN Code Numeric Bar Codes 0 5 Wireless FuzzyScan Reference Manual 3 8 6 1 4 9 7 2 Please refer to Quick Reference Guide of “Connecting FuzzyScan Bluetooth Cordless Scanners with your Apple iOS Devices” for more details.
Appendix System Commands Save Configuration PROGRAM (Enter Programming Mode) Sleep FIN (Finish) Clone Paging END (Exit Programming Mode) Factory Default PowerTool Host Link Wireless FuzzyScan Reference Manual System Information List (SYSLIST) Master Default Power Off Factory Default: After scanning” Factory Default” command, all parameters will be returned to factory default value (The radio link will be disconnected and the scanner will revert to uninstall state).
Appendix Indications Wireless FuzzyScan Reference Manual Scanner Indication Items Radio connection Link Indicator 1 blue blink per 2.5 sec. Beeping Off Radio disconnection 3 blue blinks per 2 sec. Off During connection Quick blue blinks Short clicks Radio connection built 1 blue blink per 2.5 sec. 4 beeps in ascending tone Radio connection lost 3 blue blinks per 2 sec.
Appendix Central Indicator Central Indicator Side Indicators Side Indicators HB211x / HB3112 Smart Cradle Indications Indicators Items Power on Off Power on beeps Smart Cradle Upgrade State Off Steady red Short clicks Uninstall state Off Alternative red-green blinks Off Steady blue Steady Green Off Radio Disconnected Off Steady red Off Radio Connected Off Off Radio Disconnected Off Steady red Off PICO Mode Steady blue Steady green 6 page beeps PAIR Mode Steady blue Off 6 pa
FuzzyScan Wireless Reference Manual CINO GROUP PC WORTH INT’L CO., LTD. www.cino.com.