Specifications

Command Descriptions
Programming Reference
VERSAJET MP3200
GS ( K <Function 49>
[Name] Selects printing density
[Format] ASCII GS ( K pL pH fn m
Hex 1D 28 4B 02 00 31 m
Decimal 29 40 75 2 0 49 m
[Range] (pL + pH x 256) = 2 (pL = 2, pH = 0)
fn = 49, 0 m 15
[Default] m = 8
[Description] Selects printing control mode by m.
m Function
m < 8 Selects pale density
m = 8 Selects standard density
m > 8 Selects strong density
The specification of each printing control mode differs, depending on the printer model.
See model-dependent variations.
[Notes]
When a standard mode is selected, all the data in a line is printed in the same density.
When a page mode is selected, all the data printed collectively by FF or ESC FF is printed
in the same density.
105 Preliminary Rev. 02