Specifications

Command Descriptions
Programming Reference
VERSAJET MP3200
GS ( k PDF417<Function 068>
[Format] ASCII GS ( k pL pH cn fn n
Hex 1D 28 6B 03 00 30 44 n
Decimal 29 40 107 03 00 48 68 n
[Range] (pL + pH x256) = 3 (pL=3,pH =0)
cn = 48, fn = 68, 5 n 100
[Default] n = 5
[Description] Specifies the height of a module of PDF417 symbol.
[Notes]
Settings of this function affect the processing of Functions 081.
Settings of this function are effective until ESC @ is executed, the printer is reset, or the
power is turned off.
The module height influences the recognition rate of the symbol.
The setting unit is 0.1 mm.
120 Preliminary Rev. 02