5.2.4.3 Baking
Baking conditions are specified on the moisture sensitivity label attached to each MBB:
It is not necessary to bake ALAS5V, if the conditions specified in Section 5.2.4.1 and Sec-
tion 5.2.4.2 were not exceeded.
It is necessary to bake ALAS5V, if any condition specified in Section 5.2.4.1 and Section
5.2.4.2 was exceeded.
If baking is necessary, the modules must be put into trays that can be baked to at least 125°C.
Devices should not be baked in tape and reel carriers at any temperature.
5.2.4.4 Electrostatic Discharge
Electrostatic discharge (ESD) may lead to irreversible damage for the module. It is therefore
advisable to develop measures and methods to counter ESD and to use these to control the
electrostatic environment at manufacturing sites.