Specifications

Table Of Contents
Cinterion
®
ALAS5V Hardware Interface Description
4 Operating Characteristics
96
ALAS5V_HID_v00.030a 2019-03-20
Confidential / Preliminary
Page 68 of 124
4 Operating Characteristics
4.1 Operating Modes
The table below briefly summarizes the various operating modes referred to throughout the
document.
Table 21: Overview of operating modes
Mode Function
Normal
operation
GSM / GPRS /
UMTS / HSPA /
LTE SLEEP
Power saving set automatically when no call is in progress and the USB
connection is detached and no active communication via ASC0. Also,
the GNSS active antenna mode has to be turned off or set to "auto"
GSM / GPRS /
UMTS / HSPA /
LTE IDLE
Power saving disabled or an USB connection active, but no data trans-
fer in progress.
GSM TALK/
GSM DATA
Connection between two subscribers is in progress. Power consump-
tion depends on the GSM network coverage and several connection
settings (e.g. DTX off/on, FR/EFR/HR, hopping sequences and
antenna connection). The following applies when power is to be mea-
sured in TALK_GSM mode: DTX off, FR and no frequency hopping.
GPRS DATA GPRS data transfer in progress. Power consumption depends on net-
work settings (e.g. power control level), uplink / downlink data rates and
GPRS configuration (e.g. used multislot settings).
EGPRS DATA EGPRS data transfer in progress. Power consumption depends on net-
work settings (e.g. power control level), uplink / downlink data rates and
EGPRS configuration (e.g. used multislot settings).
UMTS TALK/
UMTS DATA
UMTS data transfer in progress. Power consumption depends on net-
work settings (e.g. TPC Pattern) and data transfer rate.
HSPA DATA HSPA data transfer in progress. Power consumption depends on net-
work settings (e.g. TPC Pattern) and data transfer rate.
LTE DATA LTE data transfer in progress. Power consumption depends on network
settings, data transfer rates, and carrier aggregation/MIMO configura-
tion.
Power
Down
Normal shutdown after sending the AT^SMSO command. Software is not active. Interfaces
are not accessible. Operating voltage (connected to BATT+) remains applied. Only a volt-
age regulator is active for powering the RTC, as long as operating voltage applied at BATT+
does not drop below approx. 1.4V.
Airplane
mode
Airplane mode shuts down the radio part of the module, causes the module to log off from
the GSM/GPRS network and disables all AT commands whose execution requires a radio
connection.
Airplane mode can be controlled by AT command (see [1]).