Specifications

Cinterion
®
PLS62-W Hardware Interface Overview
1.1 Key Features at a Glance
11
t PLS62-W_hio_v02.010a 2020-08-18
Public / Released
Page 10 of 50
Power on/off, Reset
Power on/off Switch on by hardware signal IGT
Switch off by AT command
Switch off by emergency off signal (EMERG_OFF)
Switch off by hardware signal FST_SHDN instead of AT command
Automatic switch off in case of critical temperature or voltage conditions
Reset Orderly shutdown and reset by AT command
Special features
Real time clock Timer functions via AT commands
Evaluation kit
Evaluation module PLS62-W module soldered onto a dedicated PCB that can be connected to
an adapter in order to be mounted onto the DSB75.
DSB75 DSB75 Development Support Board designed to test and type approve
Thales modules and provide a sample configuration for application engi-
neering. A special adapter is required to connect the PLS62-W evaluation
module to the DSB75.
1. HTTP/SecureConnection over SSL version 3.0 and TLS versions 1.0, 1.1, and 1.2 are supported. For
details please refer to Java User’s Guide for Cinterion
®
PLS62-W.
Feature Implementation