Specifications

Table Of Contents
Cinterion
®
PLSx3 Hardware Interface Description
2.1 Application Interface
66
t PLSx3_HID_v01.002d 2021-08-24
Public / Released
Page 22 of 129
2.1.2 Signal Properties
Table 3: Signal properties (Sheet 1 of 5)
Function Signal name IO Signal form and level Comment
Power
supply
BATT+
BB
BATT+
RF
I GSM activated:
V
I
max = 4.5V
V
I
norm = 3.8V
V
I
min = 3.0V
Imax= see Table 19
___|¯¯|____________|¯¯|___
n Tx = n x 577µs peak current every
4.616ms
WCDMA activated:
V
I
max = 4.5V
V
I
norm = 3.8V
V
I
min = 3.0V during Transmit active.
Imax = see Table 20
LTE activated:
V
I
max = 4.5V
V
I
norm = 3.8V
V
I
min = 3.0V during Transmit active.
Imax = see Table 21
Lines of BATT+ and GND
must be connected in par-
allel for supply purposes
because higher peak cur-
rents may occur.
Minimum voltage must not
fall below 3.0V including
drop, ripple, spikes and not
rise above 4.5V.
Note: The module’s nor-
mal voltage range for oper-
ation lies between 3.0V
and 4.5V. For USB opera-
tion, 3.0V-4.5V is also rec-
ommended.
External
supply
voltage
V180 O Normal operation:
V
O
norm = 1.80V ±2%
I
O
max = 10mA
SLEEP mode Operation:
V
O
Sleep = 1.80V ±4%
I
O
max = 10mA
CImax = 100nF
V180 should be used to
supply level shifters at the
interfaces.
Note: V180 is not back
powering protected.
Wrong usage may back
power the module which is
forbidden.
If unused keep line open.
Test point recommended.
VGNSS O CLmax=2.2μ
V
O=
3V±2%@I
O
=-10mA
I
O
max = 10mA
Available when GNSS
antenna DC power is
enabled.
Supply volt-
age for
active
GNSS
antenna
ANT_GNS-
S_DC
IV
I
max_6V
The input current has to be limited to
50mA(antenna short circuit protection)
If unused connect to GND