Specifications

Table Of Contents
Cinterion
®
PLSx3 Hardware Interface Description
3.3 Power Saving
89
t PLSx3_HID_v01.002d 2021-08-24
Public / Released
Page 77 of 129
3.3.4 Wake-up via RTS0
RTS0 can be used to wake up PLSx3 from SLEEP mode configured with AT^SPOW. Assertion
of RTS0 (i.e., toggle from inactive high to active low) serves as wake up event, thus allowing
an external application to almost immediately terminate power saving. After RTS0 assertion,
the CTS0 line signals module wake up, i.e., readiness of the AT command interface. It is there-
fore recommended to enable RTS/CTS flow control (default setting).
Figure 31 shows the described RTS0 wake up mechanism.
Figure 31: Wake-up via RTS0
RTS0
CTS0
TXD0
RXD0
AT command
Reply URC
RTS assertion (falling edge)
Wake up from SLEEP mode
Return to SLEEP mode
RTS back