Specifications

Table Of Contents
Cinterion
®
PLSx3 Hardware Interface Description
3.4 Power Supply
82
t PLSx3_HID_v01.003 2021-03-12
Public / Released
Page 75 of 121
I
BATT+
2
(i.e., sum of
BATT+
BB
and
BATT+
RF
)
Average
GSM900
supply current
5
GPRS Data transfer
GSM900;
PCL=5; 1Tx/4Rx
ROPR=8
(max. reduction)
287 mA
ROPR=4
(no reduction)
287 mA
GPRS Data transfer
GSM900;
PCL=5; 2Tx/3Rx
ROPR=8
(max. reduction)
425 mA
ROPR=4
(no reduction)
530 mA
GPRS Data transfer
GSM900;
PCL=5; 4Tx/1Rx
ROPR=8
(max. reduction)
613 mA
ROPR=4
(no reduction)
985 mA
EDGE Data transfer
GSM900;
PCL=5; 1Tx/4Rx
ROPR=8
(max. reduction)
180 mA
ROPR=4
(no reduction)
179 mA
EDGE Data transfer
GSM900;
PCL=5; 2Tx/3Rx
ROPR=8
(max. reduction)
272 mA
ROPR=4
(no reduction)
315 mA
EDGE Data transfer
GSM900;
PCL=5; 4Tx/1Rx
ROPR=8
(max. reduction)
422 mA
ROPR=4
(no reduction)
565 mA
Table 18: Current Consumption Ratings -GSM
1
Description Conditions Typical rating
(W,EP,LA,J, I)
Unit