Specifications

Table Of Contents
Cinterion
®
PLSx3 Hardware Interface Description
1.2 Key Features at a Glance
16
t PLSx3_HID_v01.003 2021-03-12
Public / Released
Page 11 of 122
Interfaces
Module interface Surface mount device with solderable connection pads (SMT application
interface). Land grid array (LGA) technology ensures high solder joint reli-
ability and allows the use of an optional module mounting socket.
For more information on how to integrate SMT modules see also [4].This
application note comprises chapters on module mounting and application
layout issues as well as on additional SMT application development equip-
ment.
USB
(see Section 2.1.3)
USB 2.0 High Speed (480Mbit/s) device interface. Full Speed (12Mbit/s)
compliant.
2 serial interfaces
(see Section 2.1.4, and
Section 2.1.5)
ASC0 (in parts shared with GPIO lines):
8-wire modem interface with status and control lines, unbalanced, asyn-
chronous
Fixed baud rates: 300bps to 921,600bps
Supports RTS0/CTS0 hardware flow control.
ASC1 (shared with GPIO lines):
4-wire, unbalanced asynchronous interface
Fixed baud rates: 300bps to 921,600bps and 3Mbps
Supports RTS1/CTS1 hardware flow control
2 UICC interfaces
(switchable)
(see Section 2.1.6)
Supported chip cards: UICC/SIM/USIM 3V, 1.8V
GPIO interface
(see Section 2.1.7)
22 GPIO lines comprising:
13 lines shared with ASC0, ASC1 lines, with network status indication, fast
shutdown and SIM switch
9 GPIO lines not shared
I
2
C interface Supports I
2
C serial interface.
Digital audio interface
(see Section 2.1.8)
1 digital interface can be configured as PCM or I
2
S.
RING0 Support RING0 to wake up host from power saving state.
Antenna interface pads
(see Section 2.1)
50. UMTS/GSM/LTE main antenna, UMTS/LTE Rx Diversity antenna,
GNSS antenna.
ADC inputs
(see Section 2.1.9)
Analog-to-Digital Converter with unbalanced analog inputs, for example, for
the (external) antenna diagnosis
Power on/off, Reset
Power on/off Switch on by hardware signal IGT
Switch off by AT command
Switch off by hardware signal FST_SHDN instead of AT command
Automatic switch off in case of critical temperature or voltage conditions
Reset Orderly reset by AT command
Reset by emergency reset signal EMERG_RST.
Special features
Real time clock Timer functions via AT commands.
Evaluation kit
LGA DevKit LGA DevKit designed to test Thales LGA modules.
Feature Implementation