Specifications

Table Of Contents
Cinterion
®
PLSx3 Hardware Interface Description
2.1 Application Interface
60
t PLSx3_HID_v01.003 2021-03-12
Public / Released
Page 22 of 121
Ignition IGT I Do not add any voltage on it. There is
a built-in pull up resister, you can test
about 0.8V voltage on it.
¯¯|___|¯¯ low impulse width > 300ms
This signal switches the
module on. The IGT signal
characteristic is:
Power on triggered and
low level triggered. Fall
time should be <1ms.
Note: To turn on the mod-
ule please use an open-
drain/collector circuit.
Test point recommended.
Status
signaling
STATUS O V
OI
max = 0.45V at I = 1mA
V
OH
min = 1.35V at I = 1mA
V
OH
max = 1.8V
If unused keep line open.
Emer-
gency reset
EMERG_RST I Do not add any voltage on it. There is
a built-in pull up resistor to pull to GND
when Reset.
¯¯|___|¯¯ low impulse width > 200ms
This line must be driven
low by an open drain or
open collector driver con-
nected to GND.
If unused keep line open.
Test point recommended.
Fast shut-
down
FST_SHDN I V
IL
max = 0.63V
V
IH
min = 1.17V
V
IH
max = 1.8V
¯¯|___|¯¯ low impulse width > 1ms
This line must be driven
low.
If unused keep line open.
Note that the fast shut-
down line is originally
available as GPIO line. If
configured as fast shut-
down, the GPIO line is
assigned as follows:
GPIO4 --> FST_SHDN
USB VUSB_IN I V
IN
min = 3V
V
IN
max = 5.25V
Active and suspend current:
Imax<100µA
All electrical characteris-
tics according to USB
Implementers' Forum,
USB 2.0 Specification.
If unused keep lines open.
Test points recommended.
USB_DN I/O Full and high speed signal characteris-
tics according to USB 2.0 Specifica-
tion.
USB_DP
Table 3: Signal properties (Sheet 2 of 5)
Function Signal name IO Signal form and level Comment