Specifications

Table Of Contents
Cinterion
®
PLSx3 Hardware Interface Description
2.1 Application Interface
60
t PLSx3_HID_v01.003 2021-03-12
Public / Released
Page 25 of 121
ADC_IN
(Analog-to-
Digital Con-
verter)
ADC1
ADC2
ADC3
IR
I
= 10Mohm
V
I
= 0.1V ... 1.7V (valid range)
V
IH
max = 1.7V
Resolution 15 Bits
Offset error ±1%
If unused keep line open.
GPO Inter-
face
ANT_SW O V
OL
max = 0.4
V
OH
min = 1.336V
V
OH
max = 1.93V
If unused keep line open.
SIM Switch SIM_SWITCH O V
OL
max = 0.4V
V
OH
min = 1.336V
V
OH
max = 1.93V
If unused keep line open.
Power
indicator
PWR_IND O V
IH
max = 5.5V
V
OL
max = 0.4V at Imax = 2mA
PWR_IND (Power Indica-
tor) notifies the module’s
on/off state (see Section
2.1.10).
PWR_IND is an open col-
lector that needs to be
connected to an external
pullup resistor. Low state
of the open collector indi-
cates that the module is
on. Vice versa, high level
notifies the power-down
mode. Therefore, the sig-
nal may be used to enable
external voltage regulators
which supply an external
logic for communication
with the module, e.g. level
converters.
Do not connect to V180.
Table 3: Signal properties (Sheet 5 of 5)
Function Signal name IO Signal form and level Comment