Specifications

Table Of Contents
Cinterion
®
PLSx3 Hardware Interface Description
2.2 RF Antenna Interface
60
t PLSx3_HID_v01.003 2021-03-12
Public / Released
Page 49 of 121
RF Power @ ARP
with 50Ohm Load
,
(ROPR = 7, i.e. partial reduc-
tion)
GPRS, 1 TX GSM 850 33 dBm
E-GSM 900 33 dBm
DCS 1800 30 dBm
PCS 1900 30 dBm
EDGE, 1 TX GSM 850 27 dBm
E-GSM 900 27 dBm
DCS 1800 26 dBm
PCS 1900 26 dBm
GPRS, 2 TX GSM 850 30 dBm
E-GSM 900 30 dBm
DCS 1800 27 dBm
PCS 1900 27 dBm
EDGE, 2 TX GSM 850 27 dBm
E-GSM 900 27 dBm
DCS 1800 26 dBm
PCS 1900 26 dBm
GPRS, 3 TX GSM 850 28.2 dBm
E-GSM 900 28.2 dBm
DCS 1800 25.2 dBm
PCS 1900 25.2 dBm
EDGE, 3 TX GSM 850 27 dBm
E-GSM 900 27 dBm
DCS 1800 26 dBm
PCS 1900 26 dBm
GPRS, 4 TX GSM 850 27 dBm
E-GSM 900 27 dBm
DCS 1800 24 dBm
PCS 1900 24 dBm
EDGE, 4 TX GSM 850 27 dBm
E-GSM 900 27 dBm
DCS 1800 26 dBm
PCS 1900 26 dBm
Table 11: RF Antenna interface GSM/UMTS/LTE
Parameter Conditions Min. Typical Max. Unit