Specifications

Table Of Contents
Cinterion
®
PLSx3 Hardware Interface Description
3.4 Power Supply
82
t PLSx3_HID_v01.003 2021-03-12
Public / Released
Page 78 of 121
3. Measurements start 6 minutes after switching ON the module,
averaging times: SLEEP mode – 3 minutes, transfer modes – 1.5 minutes
Communication tester settings:no neighbor cells, no cell reselection etc.,
RMC (Reference Measurement Channel)
SLEEP mode is enabled via AT command AT^SPOW=2, 1000, 3
4. The power save mode is disabled via AT command AT^SPOW=1,0,0
5. The communication tester settings of Channel: Mid Channel
Table 19: Current Consumption Ratings - UMTS
1
1. Note: Current consumption ratings are based on measurements done in a laboratory test environment,
and deviations may occur from the given typical ratings. Under real life conditions however, with e.g.,
varying network quality, location changes, or changing supply currents, the deviations from these typical
ratings may be even bigger, and will have to be taken into account for actual power supply solutions. For
more details on power supply design see [3].
Description Conditions Typical
rating
(W,EP,L
A,J,I)
Typical
rating
(X, X2,
X3, X4)
Unit
I
BATT+
2
(i.e., sum of
BATT+
BB
and
BATT+
RF
)
2. With an impedance of Z
LOAD
=50 at the antenna pad. Measured at 25°C and 3.8V.
OFF State supply
current
POWER DOWN TBD TBD µA
UMTS SLEEP State
supply current
SLEEP
3
@ DRX=9
(no communication
via UART)
3. Measurements start 6 minutes after switching ON the module,
averaging times: SLEEP mode – 3 minutes, transfer modes – 1.5 minutes
Communication tester settings:no neighbor cells, no cell reselection etc.,
RMC (Reference Measurement Channel)
SLEEP mode is enabled via AT command AT^SPOW=2, 1000, 3
USB
disconnected
TBD TBD mA
USB
suspended
TBD TBD mA
SLEEP
3
@ DRX=8
(no communication
via UART)
USB
disconnected
TBD TBD mA
USB
suspended
TBD TBD mA
SLEEP
3
@ DRX=6
(no communication
via UART)
USB
disconnected
TBD TBD mA
USB
suspended
TBD TBD mA
UMTS IDLE
4
State
supply current
IDLE @ DRX=6
(UART active, but no
communication)
USB
disconnected
TBD TBD mA
USB active
TBD TBD mA
UMTS average
supply current
5
UMTS Data transfer Band I 560 mA
UMTS Data transfer Band II 530 600 mA
UMTS Data transfer Band III 480 mA
UMTS Data transfer Band IV 530 710 mA
UMTS Data transfer Band V 500 690 mA
UMTS Data transfer Band VI 500 mA
UMTS Data transfer Band VIII 530 mA