Specifications
Table Of Contents
- Contents
- Tables
- Figures
- 1 Introduction
- 2 Interface Characteristics
- 2.1 Application Interface
- 2.2 RF Antenna Interface
- 2.3 GNSS Interface
- 2.4 Sample Application
- 3 Operating Characteristics
- 3.1 Operating Modes
- 3.2 Power Up/Power Down Scenarios
- 3.3 Power Saving
- 3.4 Power Supply
- 3.5 Operating Temperatures
- 3.6 Electrostatic Discharge
- 3.7 Blocking against RF on Interface Lines
- 3.8 Reliability Characteristics
- 4 Mechanical Dimensions, Mounting and Packaging
- 4.1 Mechanical Dimensions of TX62-W
- 4.2 Mechanical Dimensions of TX82-W, TX82-W-B, TX62-W-B and TX62-W-C
- 4.3 Mounting TX62/TX82 onto the Application Platform
- 4.4 Packaging
- 5 Regulatory and Type Approval Information
- 6 Document Information
- 7 Appendix
Cinterion
®
TX62-W/TX82-W Hardware Interface Description
3.4 Power Supply
120
t TX62-W_TX62-W-x_TX82-W-x_HID_v01.200d 2022-09-08
Public / Preliminary
Page 100 of 170
I
BATT+
1
(i.e., only
BATT+
BB
)
Average
LTE CAT-
M1 supply
current
RRC con-
nected
Active
Transmis-
sion
3
TX62-W-B,
TX82-W-B,
and TX62-
W-C
4
only
Band1, 23dBm - 226 242 - TBD. mA
Band2, 23dBm - 224 - - TBD. mA
Band3, 23dBm - 230 198 - TBD. mA
Band4, 23dBm - 235 - - TBD. mA
Band5, 23dBm - 228 - - TBD. mA
Band8, 23dBm - 235 193 - TBD. mA
Band12, 23dBm - 208 - - TBD. mA
Band13, 23dBm - 220 - - TBD. mA
Band18, 23dBm - 216 - - TBD. mA
Band19, 23dBm - 224 - - TBD. mA
Band20, 23dBm - 225 187 - TBD. mA
Band25, 23dBm - 226 - - TBD. mA
Band26, 23dBm - 226 - - TBD. mA
Band27, 23dBm - 213 - - TBD. mA
Band28, 23dBm - 214 199 - TBD. mA
Band31, 26dBm (TX62-W-C) - - 235 - - mA
Band66, 23dBm - 231 - - TBD. mA
Band72, 26dBm (TX62-W-C) - - 229 - - mA
Band85, 23dBm - 201 - - TBD. mA
RRC con-
nected
Active
Transmis-
sion
3
Band1, 20dBm 168 - - 177 - mA
Band2, 20dBm 177 - - 171 - mA
Band3, 20dBm 167 - - 172 - mA
Band4, 20dBm 167 - - 169 - mA
Band5, 20dBm 175 - - 187 - mA
Band8, 20dBm 180 - - 180 - mA
Band12, 20dBm 173 - - 164 - mA
Band13, 20dBm 183 - - 185 - mA
Band18, 20dBm 179 - - 184 - mA
Band19, 20dBm 180 - - 186 - mA
Band20, 20dBm 179 - - 185 - mA
Band25, 20dBm 176 - - 173 - mA
Band26, 20dBm 183 - - 180 - mA
Band27, 20dBm 181 - - 183 - mA
Band28, 20dBm 170 - - 185 - mA
Band66, 20dBm 166 - - 169 - mA
Band85, 20dBm 168 - - 164 - mA
Table 25: Current consumption ratings Cat M1 (TX62/TX82)
Description Conditions Typical rating Unit
TX62-W TX62-W-B TX62-W-C TX82-W TX82-W-B