Specifications
Table Of Contents
- Contents
- Tables
- Figures
- 1 Introduction
- 2 Interface Characteristics
- 2.1 Application Interface
- 2.2 RF Antenna Interface
- 2.3 GNSS Interface
- 2.4 Sample Application
- 3 Operating Characteristics
- 3.1 Operating Modes
- 3.2 Power Up/Power Down Scenarios
- 3.3 Power Saving
- 3.4 Power Supply
- 3.5 Operating Temperatures
- 3.6 Electrostatic Discharge
- 3.7 Blocking against RF on Interface Lines
- 3.8 Reliability Characteristics
- 4 Mechanical Dimensions, Mounting and Packaging
- 4.1 Mechanical Dimensions of TX62-W
- 4.2 Mechanical Dimensions of TX82-W, TX82-W-B, TX62-W-B and TX62-W-C
- 4.3 Mounting TX62/TX82 onto the Application Platform
- 4.4 Packaging
- 5 Regulatory and Type Approval Information
- 6 Document Information
- 7 Appendix
Cinterion
®
TX62-W/TX82-W Hardware Interface Description
3.4 Power Supply
120
t TX62-W_TX62-W-x_TX82-W-x_HID_v01.200d 2022-09-08
Public / Preliminary
Page 110 of 170
I
BATT+
1
(i.e., only
BATT+
BB
)
Peak Current @ RRC
connected
Active Transmission UL
RMC, single tone mode
(1subcarrier),15KHz
spacing
3
VBATT=3.8V
Band1, 20dBm 388 - - 380 - mA
Band2, 20dBm 396 - - 372 - mA
Band3, 20dBm 380 - - 364 - mA
Band4, 20dBm 352 - - 368 - mA
Band5, 20dBm 416 - - 448 - mA
Band8, 20dBm 436 - - 432 - mA
Band12, 20dBm 388 - - 376 - mA
Band13, 20dBm 444 - - 436 - mA
Band18, 20dBm 420 - - 436 - mA
Band19, 20dBm 420 - - 440 - mA
Band20, 20dBm 428 - - 440 - mA
Band25, 20dBm 396 - - 376 - mA
Band26, 20dBm 436 - - 428 - mA
Band28, 20dBm 396 - - 408 - mA
Band66, 20dBm 376 - - 368 - mA
Band71, 20dBm 372 - - 368 - mA
Band85, 20dBm 388 - - 368 - mA
Peak Current @ RRC
connected
Active Transmission UL
RMC, single tone mode
(1subcarrier),15KHz
spacing
3
VBATT=2.5V (TX62-W-B)
VBATT=3.2V (TX62-W-C)
VBATT=TBD.V (TX82-W-
B)
TX62-W-B, TX82-W-B,
and TX62-W-C
4
only
Band1, 23dBm - 624 696 - TBD. mA
Band2, 23dBm - 612 - - TBD. mA
Band3, 23dBm - 612 560 - TBD. mA
Band4, 23dBm - 612 - - TBD. mA
Band5, 23dBm - 624 - - TBD. mA
Band8, 23dBm - 648 464 - TBD. mA
Band12, 23dBm - 576 - - TBD. mA
Band13, 23dBm - 624 - - TBD. mA
Band18, 23dBm - 624 - - TBD. mA
Band19, 23dBm - 624 - - TBD. mA
Band20, 23dBm - 648 512 - TBD. mA
Band25, 23dBm - 612 - - TBD. mA
Band26, 23dBm - 624 - - TBD. mA
Band28, 23dBm - 588 536 - TBD. mA
Band31, 23dBm (TX62-W-C) - - 464 - - mA
Band66, 23dBm - 624 - - TBD. mA
Band71, 23dBm (TX62-W-B) - 576 - - - mA
Band72, 23dBm (TX62-W-C) - - 480 - - mA
Band85, 23dBm - 588 - - TBD. mA
Table 26: Current consumption ratings Cat NB1/2 (TX62/TX82)
Description Conditions Typical rating Unit
TX62-W TX62-W-B TX62-W-C TX82-W TX82-W-B